SBL10U100D1
Voltage 100V 10.0 Amp
Low VF Trench Barrier Schottky Rectifier
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen free
FEATURES
TO-252
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Trench Barrier Schottky technology
Low forward voltage drop
Low reverse current
High current capability
High reliability
High surge current capability
Epitaxial construction
A
C
D
B
MECHANICAL DATA
G E
H F
ꢀ
ꢀ
ꢀ
Case: Molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
K
J
N
O
P
M
ꢀ
ꢀ
Polarity: As Marked
Mounting position: Any
Millimeter
Min. Max.
Millimeter
REF.
REF.
Min.
Max.
A
B
C
D
E
F
6.35
4.95
2.10
0.43
6.0
2.80 REF
5.40
0.60
6.90
5.50
2.50
0.9
J
K
M
N
O
P
2.30 REF.
0.64
0.50
1.3
0
1.14
1.14
1.8
PACKAGE INFORMATION
1
7.5
0.13
2
0.58REF.
Package
MPQ
Leader Size
G
H
6.40
1.20
3
TO-252
2.5K
13 inch
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise s pecified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
VRRM
VRSM
VDC
100
100
100
5
V
V
V
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current
(Per Leg)
A
IF
10
(Per Device)
IFSM
80
A
Peak Forward Surge Current, 8.3 ms single half sine-wave
Voltage Rate of Chance (Rated VR)
Typical Thermal Resistance 3
dv/dt
10000
10
V / µs
°C /W
°C
Rθ
JC
Operating and Storage Temperature Range
TJ,TSTG
-40~150
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Typ.
Max.
0.63
0.75
-
Unit
Test Condition
IF = 3A, TJ = 25°C
0.57
0.68
0.61
-
Maximum Instantaneous Forward
Voltage
VF
V
IF = 5A, TJ = 25°C
IF = 5 A, TJ = 125°C
TJ=25°C
0.1
10
Maximum DC Reverse Current
at Rated DC Blocking Voltage 2
Typical Junction Capacitance 1
IR
mA
pF
-
TJ=100°C
CJ
220
-
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0V D.C.
2. Pulse Test:Pulse Width = 300 µs, Duty Cycle ≦ 2.0%.
3. FR4 Board Heat sink size: 8*5*0.2mm.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
02-Dec-2013 Rev. A