Polyphase Energy Metering IC with Pulse Outputs
and Anti-Tamper Features
SA4301A
FEATURES
Per phase energy direction indication
Per phase missing phase indication
Phase sequence error indication
Precision on-chip oscillator (70ppm/°C drift)
Precision on-chip voltage reference (10ppm/°C drift)
On-chip anti-creep function (0.005% of EMAX
Low power consumption (<40mW typical)
Measures AC inputs only
Meets the IEC62053, CBIP-88 and IS137799-1999
specification requirements for Class 1 AC static watt-
hour meters for active energy
Motor drive outputs (MOP, MON) provide average active
power information and can drive an electro-mechanical
counter or an impulse counter directly
)
LED pulse output for calibration purposes supplies
average active power information
Configurable for different meter ratings
DESCRIPTION
The SA4301A is an accurate polyphase power/energy
metering integrated circuit providing a single chip solution for
three phase energy meters. Very few external components
are required and the chip includes a direct drive capability for
electro-mechanical counters. The SA4301A does not require
an external crystal or voltage reference. A precision oscillator
and a precision voltage reference to supply the circuitry with
a stable frequency and stable reference currents are
integrated on the chip.
currents (IMAX) and nominal voltages (VNOM) without having to
change the stepper motor counter or impulse counter gear
ratio. The LED pulse output follows the average active power
consumption measured and is intended for meter calibration
purposes. In fast calibration mode this output provides a high
frequency pulse rate following the average active power
consumption and can be used for fast calibration or to
interface with a microcontroller.
The SA4301A includes an anti-creep feature preventing any
creep effects in the meter under no-load conditions.
The SA4301A metering integrated circuit generates a pulse
output, the frequency of which is proportional to the active
power consumption.
The SA4301A integrated circuit is available in a 24 pin small
outline (SOIC24) RoHS compliant package.
Programmable inputs allow the meter manufacturer to
configure the SA4301A for different meter maximum
VDD
IIP1
IIN1
DIGITAL
OUTPUT
CURRENT
CHANNEL 1
ADC
POWER ON
RESET
SIGNAL PROCESSING
Instantaneous
PROGRAMMABLE
ADDER
Average
power
power
ANTI-CREEP
THRESHOLD
ABS
|X|
LPF
PH/DIR
IVP1
DIGITAL
OUTPUT
VOLTAGE
CHANNEL 1
ADC
TAMPER
OUTPUT
PH1
PH2
PH3
CONDITION
AND
MAINS FAIL
DETECTION DIRECTION
ENERGY
MULTIPLEXER
AND
DRIVER
STATUS SIGNAL
DETERMINATION
IIP2
IIN2
DIGITAL
OUTPUT
CURRENT
CHANNEL 2
ADC
Instantaneous
power
Average
power
ANTI-CREEP
THRESHOLD
ABS
|X|
PULSE
GENERATION
DIVISION
FOR
CALIBRATION
LED OUTPUT
LPF
LED
IVP2
DIGITAL
OUTPUT
VOLTAGE
CHANNEL 2
ADC
MAINS FAIL
DETECTION DIRECTION
ENERGY
IIP3
IIN3
DIGITAL
OUTPUT
CURRENT
CHANNEL 3
ADC
MODE
MS
RA
Instantaneous
power
Average
power
CHANNEL
ANTI-CREEP
THRESHOLD
ABS
|X|
PIN STATE
DETECTION
LPF
IVP3
DIGITAL
OUTPUT
RB
VOLTAGE
CHANNEL 3
ADC
MAINS FAIL
DETECTION DIRECTION
ENERGY
AGND
FMS
DIVISION
FOR
COUNTER OUTPUT
VOLTAGE REFERENCE
AND
OSCILLATOR
AND
CURRENT BIASING
TIMING
COUNTER
DRIVE
BUFFERS
VREF
MON
MOP
VSS
Figure 1: Block diagram
SPEC-1538 (REV. 7)
29-09-2017
1/23