Single Channel Single Phase Energy
Metering IC
SA4104A / SA4104B
FEATURES
Configurable for different meter ratings
Precision on-chip oscillator (70ppm/°C drift)
Precision on-chip voltage reference (10ppm/°C drift)
On-chip anti-creep function (0.01% of FMAX on SA4104A
or 0.004% of FMAX on SA4104B)
Meets the IEC62053, CBIP-88 and IS137799-1999
specification requirements for Class 1 AC static watt-
hour meters for active energy
Motor drive outputs (MOP, MON) provide average active
power information and can drive an electro-mechanical
counter or an impulse counter directly
Low power consumption (<20mW typical)
Measures AC inputs only
LED pulse output for calibration purposes supplies
average active power information
DESCRIPTION
The SA4104A/B is an accurate single phase power/energy
metering integrated circuit providing a single chip solution for
single phase energy meters. Very few external components
are required and the chip includes a direct drive capability for
electro-mechanical counters. The SA4104A/B does not
require an external crystal or voltage reference. A precision
oscillator and a precision voltage reference to supply the
circuitry with a stable frequency and stable reference currents
are integrated on the chip.
The LED pulse output follows the average active power
consumption measured and is intended for meter calibration
purposes. In fast calibration mode this output provides a high
frequency pulse rate following the average active power
consumption and can be used for fast calibration or to
interface with a microcontroller.
The SA4104A/B includes an anti-creep feature preventing
any creep effects in the meter under no-load conditions. Two
versions of the device are available, namely the SA4104A
and SA4104B. The only difference between the two versions
is the anti-creep threshold. The anti-creep threshold is set to
0.01% of FMAX on the SA4104A and 0.004% of FMAX on the
SA4104B.
The SA4104A/B metering integrated circuit generates a pulse
output, the frequency of which is proportional to the active
power consumption.
Programmable inputs allow the meter manufacturer to
configure the SA4104A/B for different meter maximum
currents (IMAX) and nominal voltages (VNOM) without having to
change the stepper motor counter or impulse counter gear
ratio.
The SA4104A/B integrated circuit is available in a 16 pin
small outline (SOIC16) RoHS compliant package.
VDD
DIRO
FMS
POWER ON
RESET
PIN STATE
DETECTION
DIGITAL
OUTPUT
IIP
SIGNAL PROCESSING
CURRENT
CHANNEL
ADC
IIN
Instantaneous
power
Average
power
LED
PULSE
GENERATION
DIVISION
FOR
LPF
CALIBRATION
LED OUTPUT
DIGITAL
OUTPUT
IVP
VOLTAGE
CHANNEL
ADC
R0
R1
R2
R3
AGND
VOLTAGE REFERENCE
AND
CURRENT BIASING
OSCILLATOR
AND
TIMING
DIVISION
FOR
COUNTER OUTPUT
COUNTER
DRIVE
BUFFERS
VREF
VSS
MON
MOP
Figure 1: Block diagram
SPEC-1654 (REV. 4)
29-09-2017
1/18