DESIGNED & DIMENSIONED
IN MILLIMETERS[INCHES]
S2SDX-XX-XXX-XX-XX.XX-XX-XXX
TEFLON CABLE OPTION
REVISION V
-NXX OPTION (END 2)
(ONLY AVAILABLE WITH -D, -DL, -DR, -DS)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO N-1) (SEE FIG 2)
-T: TEFLON (AVAILABLE WITH
24, 28 & 30AWG ONLY)
(LEAVE BLANK FOR STANDARD
PVC INSULATION)
DO NOT
SCALE FROM
THIS PRINT
2.00 .079 REF
"A"REF
N (SEE TABLE 1)
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO 2) (SEE FIG 4)
No OF POSITONS
-02, -04, -05, -07, -10, -15, -20,
-25, & -30 (PER ROW)
AVAILABLE AS STANDARD
-05 THRU -50 AVAILABLE AS ASO
-NUX: NOTCH UP, CROSSED
(PIN 1 TO N) (SEE FIG 3)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO 1) (SEE FIG 5)
02
7.52 .296
REF
2.00 .079 REF
WIRE GAUGE (AWG)
-24, -26, -28, & 30
END OPTION
-S: SINGLE ENDED (SEE FIG 1)
-D: DOUBLE ENDED (SEE FIG'S 2, 3, 4, 5, 6, & 7)
-SR: SINGLE ENDED WITH RETENTION LATCH
(SEE FIG 6)
01
3.32 .131 REF
COLOR CODE:
N-1 (SEE TABLE 1)
(LEAVE BLANK FOR ALL BLACK WIRE)
-C: COLOR CODED WIRE, SEE TABLE 3,
SHEET 3 FOR COLOR SEQUENCE
(AVAILABLE WITH 24 AWG ONLY &
NOT AVAILABLE WITH TEFLON)
-DR: DOUBLE ENDED WITH RETENTION LATCH
(SEE FIG 7)
-SS: DUAL SCREW DOWN, SINGLE ENDED CABLE
(SEE FIG 8 , SHT 3) (ONLY AVAILABLE UP TO
30 POSITIONS) (USES ISD2-XX-D-DS,
CPS-RR-M2-01-N, AND ACCRT-01)
-DS: DUAL SCREW DOWN, DOUBLE ENDED CABLE
(SEE FIG 9, SHT 3) (ONLY AVAILABLE UP TO
30 POSITIONS) (USES ISD2-XX-D-DS,
CPS-RR-M2-01-N, AND ACCRT-01)
PLATING SPECIFICATION
-L: LIGHT SELECTIVE
-S: SELECTIVE
"B" REF
"C" REF
4.39 .173 REF
"A"
5.29 .208 REF
4.42 .174
REF
ASSEMBLED LENGTH
SPECIFY IN INCHES
SINGLE ENDED: 02.75 INCH MINIMUM
DOUBLE ENDED: 02.75 INCH MINIMUM
11.38 .448
REF
ISD2-XX-D
** = NOT RELEASED FOR PRODUCTION
1.60 .063 REF
ASSEMBLED LENGTH
(SEE NOTE 8)
C
SFSD: DWC-XX-XX-300
SFSDT: DWCT-XX-XX-XX
"A"
REPRESENTS A CRITICAL DIMENSION.
NOTES:
C
SECTION "A"-"A"
1.
FIG 1
2. MINIMUM PULLOUT FORCE: 11.1N [2.5LBS].
3. CONTACTS MUST BE INSERTED UNTIL RETENTION
FEATURES LOCK INTO PLACE.
S2SDX-05-24-X-XX.XX-S SHOWN
C
C
4. ALL FINISHED GOODS ARE TO BE ELECTRICALLY
TESTED INCLUDING HI-POT TEST AT 1000 VOLTS DC.
AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY WITH (1) ET STAMP
ON THE BODY.
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
*
*
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN MILLIMETERS.
TOLERANCES ARE:
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
6. PARTS TO BE LAYER PACKAGED.
DECIMALS
ANGLES
7. END OF DISCRETE WIRE MUST FALL WITHIN THIS RANGE AFTER CRIMP.
8. FOR LENGTHS OF 12.00 INCHES AND LESS, TOLERANCE TO BE ± 3.18[.125],
FOR LENGTHS GREATER THAN 12.00 INCHES, TOLERANCE TO BE ± 2%
9. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,
TOLERANCES, TOOLING AND ITS REQUIREMENTS.
X.X: 0.3 [.01]
X.XX: 0.13 [.005]
2
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
X.XXX: 0.051 [.0020]
e-Mail info@SAMTEC.com
SHEET SCALE: 2:1
MATERIAL:
DO NOT SCALE DRAWING
INSULATOR: LCP, COLOR: BLACK
DESCRIPTION:
10. NOTE DELETED
CONTACT: BeCU
CABLE INSULATION
2.00mm SOCKET DISCRETE CABLE ASSEMBLY
DWG. NO.
11. -TC TEFLON IS TO BE USED EXCLUSIVE WITH DOUBLE ENDED ASSEMBLIES,
ALL SINGLE ENDED ASSEMBLIES USE SILVER PLATED DWCT-XX-01.
12. CUT LENGTH IS ASSEMBLY LENGTH MINUS OVERALL LENGTH SUBTRACTOR.
13. DUAL POLARIZATION FEATURE NOT AVAILABLE ON BODIES LESS THAN 5 POSITIONS.
S2SD: PVC, COLOR: (SEE 'COLOR CODE')
S2SDT: TEFLON, COLOR: BLUE
CABLE WIRE
S2SD: TINNED COPPER
S2SDT: SILVERED COPPER or TINNED COPPER (SEE DWCT PRINT FOR OPTIONS)
F:\DWG\MISC\MKTG\S2SDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW
S2SDX-XX-XXX-XX-XX.XX-XX-XXX
SHEET 1 OF 4
BY:
J. BORGELT 2/20/09