S11ME5/S11ME6/S21ME5/S21ME5F/S21ME6/S21ME6F
Phototriac Coupler Conformable to
S11ME5/S11ME6/S21ME5F
European Safety Standard
S21ME5/S21ME6/S21ME6F
(
)
(
)
❈ Lead forming type I type of / S21ME5F/ S21ME6F are also available. / S21ME5FI/ S21ME6FI
❈ DIN-VDE0884 approved type is also available as an option.
(
)
■ Features
■ Outline Dimensions
Unit : mm
1. Internal isolation distance : 0.4mm or more
2. Creepage distance : 6.4mm or more
3. Clearance : 6.4mm or more
4. Recogized by UL file No. E64380
S11ME5/S11ME6
S21ME5/S21ME6
S21ME5F/S21ME6F
Anode mark
S11ME5
Anode mark
1
2
4
(
)
Approved by VDE DIN-VDE0884 : No.76850
S21ME5
(
)
Approved by BSI BS415 : No.6690, BS7002 : No.7421
3
(
)
Approved by SEMKO No.9202227
6.5±
0.5
6.5±
0.5
(
)
Approved by DEMKO No.107968
(
)
7.62±
4.58±
7.62±
0.3
Approved by EI No.152029-02,03,04,0116
0.3
0.1
0.5
4.58±
0.5
5. Built-in zero-cross circuit
(
)
S11ME6/S21ME6/S21ME6F
(
)
6. Wide forming type S21ME5F, S21ME6F
0.26±
0.5
0.1
0.26±
10.16±
(
)
Distance between lead pins : 10.16 mm
θ
0.5±
0.1
0.5±
0.1
θ : 0 to 13˚
7. High isolation voltage between input and
output
Internal connection diagram
S11ME5/S21ME5/S21ME5F
S11ME6/S21ME6/S21ME6F
(
)
Viso : 5 000V
rms
4
3
4
3
■ Applications
2
1
1. For triggering medium/high power triac
2. For detecting over voltage of switching
power supply
1
2
1
2
3
Anode
4
Anode/
Cathode
Zero-cross circuit
Cathode
Anode/
Cathode
(
)
■ Absolute Maximum Ratings
Ta = 25˚C
Parameter
Symbol
IF
Rating
Unit
mA
V
Forward current
Input
50
6
Reverse voltage
VR
RMS ON-state current
1 Peak one cycle surge current
IT
100
mArms
A
Isurge
1.2
Output
S11ME5 /S11ME6
2 S21ME5 /S21ME6
400
Repetitive peak
OFF-state voltage
3 Isolation voltage
VDRM
V
600
V
iso
5 000
- 30 to +100
- 55 to +125
260
Vrms
˚C
Operating temperature
Storage temperature
4 Soldering temperature
Topr
Tstg
Tsol
˚C
˚C
1 50Hz sine wave 2 Also S21ME5F/ S21ME6F
3 40 to 60% RH, AC for 1 minute, f= 60Hz
4 For 10 seconds
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”