● Safety standards and approvals:
EN 60950 certified, rated for
250VAC (LVD test report)
● UL-60950-1 / CSA C22.2 certified
● 6kVDC Isolation
● UL94V-0 Package Material
● Internal SMD Construction
● Fully Encapsulated
ECONOLINE
Features
DC/DC-Converter
Unregulated
Converters
RV
Series
● Efficiency to 82%
Selection Guide
Part Number
Input
Voltage
Rated Output
Voltage
Output Current
Full Load
2 Watt
DIP24 Miniature
DIP24 Miniature
(VDC)
(VDC)
3.3
5
(mA)
600
400
222
167
133
83
RV-xx3.3S
RV-xx05S
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 9, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
RV-xx09S
9
&
Single
RV-xx12S
12
15
24
3.3
5
RV-xx15S
RV-xx24S
Dual Output
RV-xx3.3D
RV-xx05D
300
200
111
83
RV-xx09D
9
RV-xx12D
12
15
24
RV-xx15D
67
RV-xx24D
42
xx = Input Voltage Range
Description
The RV Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them ideal for all
Telecom and safety applications where approved isolation is required and UL-60950-1 / CSA C22.2.
Specifications (Core Operating Area)
Input Voltage Range
10ꢀ
Output Voltage Accuracy
Line Voltage Regulation
5ꢀ
1.2ꢀ/1ꢀ of Vin max.
Load Voltage Regulation
(10ꢀ to 100ꢀ full load)
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
20ꢀ max.
15ꢀ max.
10ꢀ max.
Derating-Graph
(Ambient Temperature)
Output Ripple and Noise (20MHz limited)
Operating Frequency
200mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
70ꢀ min. / 75ꢀ typ.
Efficiency at Full Load
100
80
No Load Power Consumption
282mW min. / 338mW typ. / 400mW max.
Isolation Voltage
Rated Working Voltage
(tested for 1 second)
(long term isolation)
6.000VDC min.
see Application Notes
60
Safe Operating Area
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
2pF min. / 12pF max.
15 GΩ min.
40
20
0
1 Second
-40
0
50
100 150
Operating Temperature Range (free air convection)
Storage Temperature Range
-40°C to +85°C (see Graph)
-55°C to +125°C
95ꢀ RH
85
Operating Temperature °C
Relative Humidity
Package Weight
MSL Level 1
9g
1154 x 103 hours
Detailed Information see
Application Notes chapter "MTBF"
MTBF (+25°C)
(+85°C)
using MIL-HDBK 217F
using MIL-HDBK 217F
168 x 103 hours
}
80
April-2005
www.recom-international.com