25W Single Output Switching Power Supply
RS-25 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
No load power consumption<0.5W
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
RS-25-3.3
RS-25-5
RS-25-12
RS-25-15
RS-25-24
RS-25-48
DC VOLTAGE
3.3V
6A
5V
12V
15V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
5A
2.1A
1.7A
1.1A
0.57A
0 ~ 6A
19.8W
0 ~ 5A
25W
0 ~ 2.1A
25.2W
120mVp-p
10.8 ~ 13.2V
1.0%
0 ~ 1.7A
25.5W
120mVp-p
13.5 ~ 16.5V
1.0%
0 ~ 1.1A
26.4W
120mVp-p
22 ~ 27.6V
1.0%
0 ~ 0.57A
27.36W
200mVp-p
42 ~ 54V
1.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 2.0%
80mVp-p
4.75 ~ 5.5V
2.0%
OUTPUT
2.85 ~ 3.6V
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1800ms, 23ms/230VAC
4000ms, 30ms/115VAC at full load
14ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
HOLD UP TIME (Typ.)
VOLTAGE RANGE
80ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY(Typ.)
73.5%
78.5%
81.5%
83.5%
86%
85%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
0.7A/115VAC
0.4A/230VAC
COLD START 30A/230VAC
<2mA / 240VAC
110 ~ 180% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V
PROTECTION
ENVIRONMENT
27.6 ~ 32.4V
55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Shut off o/p voltage, clamping by zener diode
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
SAFETY &
EMC
(Note 6)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
EMS IMMUNITY
MTBF
309.7Khrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
78*51*28mm (L*W*H)
0.2Kg; 60pcs/13Kg/0.46CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:RS-25-SPEC 2010-10-18