ECONOLINE - DC/DC-Converter
RI Series, 2 Watt, SIP4 (Single Output)
Features
● 1kVDC Isolation
● No Heatsink Required
● Custom Solutions Available
● UL94V-0 Package Material
● No Extern. Components Required ● Efficiency to 80%
Selection Guide
Part
Number
SIP4
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(%)
70
75
72
76
78
80
80
RI-XX3.3
RI-XX05
RI-XX07
RI-XX09
RI-XX12
RI-XX15
RI-XX24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
3.3
5
606
400
285
222
168
132
83
7
9
12
15
24
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
10%
Capacitor Type
5%
Input Filter
Output Voltage Accuracy
Line Voltage Regulation
4.0
1,2%/1% V Input
Load Voltage Regulation
(10% to 100% full load)
3.3V output type
5V output type
7V, 9V, 12V, 15V, 24V output types
20% max.
15% max.
10% max.
3.0
2.0
1.0
0
Efficiency at Full Load
Isolation Voltage
70% min.
1.000VDC min.
Safe Operating Area
Isolation Resistance (Viso = 500VDC)
Isolation Capacitance
10 GΩ min.
30pF min./85pF max.
1 Second
-40
0
50
100
85 125
Operating Temperature ˚C
150
Short Circuit Protection
Switching Frequency at Full Load
Operating Temperature
Storage Temperature
35kHz min. / 85kHz max.
–40°C to +85°C (see Graph)
-55°C to +125°C
1.4g
Package Weight
www.recom-international.com
August 2002
EC 51