HIGH FREQUENCY
RG RELAYS WITH 1C
AND 2C CONTACTS
RG-RELAYS
25
.984
19
.748
• Excellent high frequency characteristics
Isolation: Min. 65dB (at 900 MHz)
Insertion loss: Max. 1.0 (at 900 MHz)
• Wide selection
Characteristic impedance: 50 Ω type and 75 Ω type
Coil: Single side stable and latching type
• 1 A 24 V DC switching capacity
10.4
.409
25
.984
23
.906
1 Form C
9.9
.390
• Sealed construction for automatic cleaning
• High sensitivity 350W (1 Form C) in small size
2 Form C
mm inch
SPECIFICATIONS
Contact
Characteristics
Initial insulation resistance*1
Arrangement
1 Form C, 2 Form C
Gold-clad silver
Min. 100 MΩ at 500 V DC
Contact material
Between open contacts
Between contacts and coil
Between contacts and
earth terminal
1,000 Vrms
2,000 Vrms
Initial
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
breakdown
voltage*2
100 mΩ
24 W
500 Vrms
Max. switching power
Operate time*3 (at nominal voltage)
Release time*3 (at nominal voltage)(without diode)
Set time*3 (at nominal voltage)
Approx. 10 ms
Approx. 5 ms
Approx. 7 ms
Approx. 7 ms
Max. switching voltage
Max. switching current
Nominal switching capacity
24 V DC
1 A
Rating
(resistive)
1 A 24 V DC
Reset time*3 (at nominal voltage)
High frequency characteristics
(at 900 MHz)
Max. 55°C with nominal coil voltage
50 Ω
75 Ω
Temperature rise (at 20°C)
across coil and at nominal switching capacity
Isolation
Min. 65 dB
Max. 1 dB
Max. 1.2
Min. 65 dB
Max. 1 dB
Max. 2.0
Functional*4
Shock resistance
Min. 196 m/s2 {20 G}
Min. 980 m/s2 {100 G}
10 to 55 Hz
at double amplitude of 2 mm
10 to 55 Hz
Insertion loss
V.S.W.R.
Destructive*5
Functional*6
5×106
105
Mechanical
Expected life
(min. operations)
Vibration resistance
Electrical 1 A 24 V DC
Destructive
at double amplitude of 2 mm
Coil (polarized) (at 25°C, 68°F)
Conditions for operation,
transport and storage
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–50°C to 60°C
–58°F to 140°F
1 Form C
350 mW
175 mW
350 mW
2 Form C
400 mW
200 mW
400 mW
Single side stable
1 coil latching
2 coil latching
Humidity
1 C type
2 C type
5 to 85%R.H.
Approx. 8 g .282 oz
Approx. 10 g .353 oz
Unit weight
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Intial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
TYPICAL APPLICATIONS ORDERING INFORMATION
• Measuring instrument
• Testing equipment
• CATV converter
• Audio visual equipment
• TV game set
Ex. RG
1
T
L
5V
Contact arrangement
Characteristic impedance
Operating function
Coil voltage
Nil: Single side
Nil: stable
L: 1 coil latching
L2: 2 coil latching
DC: 3, 5, 6,
9, 12, 24,
48 V
1:1 Form C
2:2 Form C
Nil: 75 Ω
T: 50 Ω
Note: Standard packing; Carton: 50 pcs. Case 500 pcs.