TECHNICAL DATA SHEET
RC12-2.5
Single-Stage Thermoelectric Module
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
Δ Tmax (°C-dry N2):
Qmax (watts):
27°C
66
23
50°C
74
26
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
Device ZT
2.5
14.7
4.9
2.5
16.4
--
0.77
--
MECHANICAL CHARACTERISTICS
*NOTE: Cold side and positive and negative leads are valid only for thermoelectric cooling. For power
generation, refer to page 3.
ORDERING OPTIONS
PRODUCT FEATURES
Model Number
Description
Rated operating temperature 160°C for short periods,
130°C extended operation
Superior nickel diffusion barriers on elements
High strength for rugged environment
Porch configuration for high strength lead wire connection
RTV sealing option available
Lapped option available for multiple module applications
-11S: Leadwire solder joints and pads are sealed with RTV.
RC12-2.5-01
Leadwires
Leadwires, Lapped
Leadwires, Sealed
Leadwires, Lapped, Sealed
Leadwires (4.4”), Lapped, Sealed
Leadwires (6.5”), Sealed
RC12-2.5-01L
RC12-2.5-01S
RC12-2.5-01LS
RC12-2.5-02LS
RC12-2.5-11S
For customer support or general questions please contact a local office or visit our website at www.marlow.com.