IR Receiver Modules
Opto Electronics Co., Ltd
R3□□H3□
(Unit : mm)
DIMENSIONS
The R3□□H3□ consist of a PIN Photodiode of high
speed and a preamplifier IC in the package as an
receiver for infrared remote control systems
Supply Voltage & Pinning
Model NO.
R31□H3□
R32□H3□
R33□H3□
R34□H3□
R35□H3□
R36□H3□
Voltage
4.5~6.0
2.7~6.0
4.5~6.0
2.7~6.0
4.5~6.0
2.7~6.0
Pinning
1=GND, 2=Vs, 3=Vout
1=Vout, 2=GND, 3=Vs
1=Vout, 2=Vs, 3=GND
FEATURES
․ One mold small package
․ 5 Volt supply voltage, low power consumption
․ Shielded against electrical field disturbance
․ High immunity against ambient light
․ Easy interface with the main board
․ TTL and CMOS compatibility
APPLICATIONS
․ TV, VTR, Acoustic Devices, Air Conditions, Car
Stereo Units, Computers, Interior controlling
appliances, and all appliances that require remote
controlling
(Ta=25℃ Unless
otherwise noted)
MAXIMUM RATINGS
Parameter
Supply Voltage
B.P.F CENTER FREQUENCY
Model NO.
R3□DH3□
R3□EH3□
R3□FH3□
R3□GH3□
R3□JH3□
B.P.F Center Frequency
32.7 kHz
Symbol
Rating
6.0
Unit
Vcc
Topr.
Tstg.
Tsol.
V
36.7 kHz
37.9 kHz
40.0 kHz
56.7 kHz
Operating Temperature
Storage Temperature
Soldering Temperature
-10~+60
-20~+75
℃
℃
260(Max 5sec)
℃
(Ta=25℃), Vcc=5.0V
ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Supply Voltage
Current Consumption
Peak Wavelength
Symbol
Vcc
Icc
λp
fo
Conditions
Min
2.7
0.5
-
Typ.
-
-
940
37.9
-
Max.
6.0
1.7
-
-
-
Unit.
V
mA
nm
kHz
m
Input Signal=0
B.P.F Center Frequency
-
0˚
±30˚
20
15
4.8
-
500
500
Transmission Distance *1
L
200±50lx
-
-
-
H Level Output Voltage *1
L Level Output Voltage *1
H Level Output Pulse Width *1
L Level Output Pulse Width *1
Output Form
VOH
VOL
TWH
TWL
30Cm over the ray
axis
Burst Wave=600㎲
Period=1.2ms
5.0
0.2
600
600
V
V
㎲
㎲
0.4
700
700
Active Low Output
Note
:
*1. It specifies the maximum distance between emitter and detector that the output waveform satisfies the standard under the conditions below against the
standard transmitter
1) Measuring place
: Indoor without extreme reflection of light
2) Ambient light source
3) Standard transmitter
:
Detecting surface illumination shall be irradiate 200±50lx under ordinary white fluorescence lamp without high frequency lightning
Burst wave of standard transmitter shall be arranged to 50mVp-p under the measuring circuit
: