QAE100
QAE100 SERIES
QUARTER-BRICK DC-DC CONVERTER
2:1 ULTRA WIDE INPUT RANGE
UP TO 108Watts
FEATURES
• NO MINIMUM LOAD REQUIRED
APPLICATIONS
• WIRELESS NETWORK
• LOW STANDBY POWER CONSUMPTION
• 2250VDC INPUT TO OUTPUT BASIC INSULATION
• SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1
• CE MARKED
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT
• COMPLIANT TO RoHS II & REACH
LOW
STANDBY
POWER
2250VDC
ISOLATION
REMOTE
CONTROL
UVP
OCP
SCP
OVP
OTP
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Output Current
@Full Load
Input Current
@ No Load
Maximum
Capacitor Load
Input Range
Output Voltage
Efficiency
Model
Number
VDC
VDC
3.3
5
12
15
24
30
48
3.3
5
12
15
24
30
48
3.3
5
12
15
24
30
48
A
25
18
7.5
6
mA
50
50
50
50
50
50
50
25
25
25
25
25
25
25
15
15
15
15
15
15
15
%
µF
QAE100-12S3P3
QAE100-12S05
QAE100-12S12
QAE100-12S15
QAE100-12S24
QAE100-12S30
QAE100-12S48
QAE100-24S3P3
QAE100-24S05
QAE100-24S12
QAE100-24S15
QAE100-24S24
QAE100-24S30
QAE100-24S48
QAE100-48S3P3
QAE100-48S05
QAE100-48S12
QAE100-48S15
QAE100-48S24
QAE100-48S30
QAE100-48S48
8.5 ~ 22
8.5 ~ 22
8.5 ~ 22
8.5 ~ 22
8.5 ~ 22
8.5 ~ 22
8.5 ~ 22
16.5 ~ 36
16.5 ~ 36
16.5 ~ 36
16.5 ~ 36
16.5 ~ 36
16.5 ~ 36
16.5 ~ 36
33 ~ 75
89
90
91
91
90
90
89
89
90
91
91
92
91
89
89
91
90
91
93
92
91
75000
36000
6250
4000
1540
1000
380
75000
36000
6250
4000
1540
1000
380
75000
42000
7500
4600
1870
1160
460
3.7
3
1.8
25
18
7.5
6
3.7
3
1.8
25
21
9
33 ~ 75
33 ~ 75
33 ~ 75
33 ~ 75
33 ~ 75
33 ~ 75
7
4.5
3.5
2.2
PART NUMBER STRUCTURE
QAE100 - 48
S
05 - P
HS
Heat-sink
Series Name
Input
Output
Output
Voltage
(VDC)
3P3:3.3
05:5
Ctrl and
Voltage
(VDC)
12:8.5~22
24:16.5~36
48:33~75
Quantity
Pin Options
and Mounting Hole Tread Options
S:Single
ꢀ:Negative logic
P:Positive logic
ꢀ:NC
HS:H=0.24” Horizontal, 7G-0029A-F
HS1:H=0.5” Horizontal, 7G-0030A-F
HS2:H=0.24” Vertical, 7G-0031A-F
HS3:H=0.5” Vertical, 7G-0032A-F
TH:Through hole (No thread) (1)
12:12
15:15
24:24
30:30
48:48
(1) The module can’t equip Heat-sink with TH option.
www.PDUKE.com
1