Q24S25018 DC-DC Converter Data Sheet
18-36 VDC Input; 1.5 VDC @ 25A Output
Description
The Q24S25018 surface mounted DC-DC converter offers
unprecedented performance in the industry-standard quarter
brick format. This is accomplished through the use of patent
pending circuit and packaging techniques to achieve ultra-
high efficiency, excellent thermal performance and a very
low body profile.
In telecommunications applications theQFamily 25 A con-
verters provide thermal performance that far exceeds all
quarter-bricks and is comparable even to existing half-bricks.
Low body profile and the preclusion of heat sinks minimize
airflow shadowing, thus enhancing cooling for downstream
devices. The use of 100% surface-mount technologies for
assembly, coupled with Power-One’s advanced electronic
and thermal circuitry and packaging, results in a product with
extremely high quality and reliability.
Q24S25018 Converter
Features
RoHS lead-free solder and lead-solder-exempted
products are available
Delivers up to 25 A
Higher current capability at 70 ºC than existing quarter
brick and half-brick converters
High efficiency: 85% @ 25 A, 85% @ 12.5 A
Start-up into pre-biased output
No minimum load required
No heat sink required
Low profile: 0.26” [6.6 mm]
Low weight: 1 oz [28 g] typical
Industry-standard footprint: 1.45” x 2.30”
Meets Basic Insulation Requirements of EN60950
On-board LC input filter
Fixed-frequency operation
Fully protected
30
25
20
15
500 LFM (2.5 m/s)
400 LFM (2.0 m/s)
10
5
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
30 LFM (0.15 m/s)
0
20
30
40
50
60
70
80
90
Ambient Temperature [°C]
Remote output sense
Fig. 1: Available load current vs. ambient air temperature and air-
flow rates for Q24S25018 converter mounted vertically with air flow-
ing from pin 3 to pin 1, MOSFET temperature 120C, Vin = 27 V.
Output voltage trim range: +10%/-20%
Trim resistor via industry-standard equations
High reliability: MTBF 2.6 million hours, calculated per
Telcordia TR-332, Method I Case 1
Positive or negative logic ON/OFF option
UL 60950 recognized in U.S. & Canada, and DEMKO
certified per IEC/EN 60950
Meets conducted emissions requirements of FCC
Class B and EN55022 Class B with external filter
All materials meet UL94, V-0 flammability rating
Applications
Telecommunications
Data communications
Wireless
Servers
MDC10152 Rev.1.0, 6-Apr-10
Page 1 of 14