5秒后页面跳转
PXU400C0 PDF预览

PXU400C0

更新时间: 2024-10-16 01:05:03
品牌 Logo 应用领域
美国红狮 - REDLION /
页数 文件大小 规格书
32页 1906K
描述
MODEL PXU - TEMPERATURE/PROCESS CONTROLLERS

PXU400C0 数据手册

 浏览型号PXU400C0的Datasheet PDF文件第2页浏览型号PXU400C0的Datasheet PDF文件第3页浏览型号PXU400C0的Datasheet PDF文件第4页浏览型号PXU400C0的Datasheet PDF文件第5页浏览型号PXU400C0的Datasheet PDF文件第6页浏览型号PXU400C0的Datasheet PDF文件第7页 
Bulletin No. PXU-D  
Drawing No. LP0932  
Released 09/15  
Tel +1 (717) 767-6511  
Fax +1 (717) 764-0839  
www.redlion.net  
MODEL PXU - TEMPERATURE/PROCESS CONTROLLERS  
z PID CONTROL  
z ACCEPTS TC and RTD  
z ACCEPTS 0-10 V, 0/4-20 mA or 0-50 mV SIGNALS  
z FUNCTIONS AS A DIGITAL POT  
z ON DEMAND AUTO-TUNING OF PID SETTINGS  
z DC ANALOG CONTROL OUTPUT (OPTIONAL)  
z 2 USER PROGRAMMABLE FUNCTION BUTTONS  
z PC (MODELS WITH RS 485) OR FRONT PANEL PROGRAMMING  
z 1/16, 1/8 or 1/4 DIN  
z CONTROLLERS MEET IP65 REQUIREMENTS  
U
R
C L US LISTED  
13RW  
PROCESS CONTROL EQUIPMENT  
The PXU is constructed of a lightweight, high impact, black plastic textured  
case with a clear display window. Modern surface-mount technology, extensive  
testing, plus high immunity to noise interference makes the controller extremely  
reliable in industrial environments.  
GENERAL DESCRIPTION  
The PXU controller accepts signals from a variety of temperature sensors  
including thermocouple or RTD. The controller can also be configured for  
process inputs including 0 to 5/10 VDC, 0/4 to 20 mA DC, or 0 to 50 mV DC.  
The PXU can provide an accurate output control signal (time proportional or DC  
Analog Output) to maintain a process at a determined setpoint value. Dual  
4-digit display readings allow viewing of the temperature/process and setpoint  
value simultaneously. Front panel indicators inform the operator of alarm and  
control output status. Comprehensive programming features allow this controller  
to meet a wide variety of application requirements.  
SAFETY SUMMARY  
All safety related regulations, local codes and instructions that appear in the  
manual or on equipment must be observed to ensure personal safety and to  
prevent damage to either the instrument or equipment connected to it. If  
equipment is used in a manner not specified by the manufacturer, the protection  
provided by the equipment may be impaired.  
MAIN CONTROL  
Do not use this unit to directly command motors, valves, or other actuators not  
equipped with safeguards. To do so can be potentially harmful to persons or  
equipment in the event of a fault to the controller. If redundant safeguards are not  
in place, an independent and redundant temperature limit indicator with alarm  
outputs is strongly recommended.  
The PXU allows the user to select between PID, On/Off and Manual control  
mode. The PXU has the ability to provide 2 control outputs. The control outputs  
can be individually configured for Reverse or Direct (heating or cooling)  
applications. The PID tuning constants can be established via on-demand auto-  
tune. The PID constants can also be programmed, or fine-tuned, through the  
front panel or a PC and then locked out from further modification.  
CAUTION: Risk of Danger.  
Read complete instructions prior to  
installation and operation of the unit.  
ALARMS  
Alarm(s) can be configured independently for absolute high or low acting  
with balanced or unbalanced hysteresis. They can also be configured for  
deviation and band alarm. In these modes, the alarm trigger values track the  
setpoint value. Adjustable alarm hysteresis can be used for delaying output  
response. The alarms can be programmed for Automatic or Latching operation.  
A selectable standby feature suppresses the alarm during power-up until the  
temperature stabilizes outside the alarm region.  
CAUTION: Risk of electric shock.  
When the power is on, DO NOT touch the AC terminals, an electric shock may  
occur. Make sure the power is disconnected when you check the input power  
supply.  
1. Prevent dust or metallic debris from falling into the controller and causing malfunctions. DO  
NOT modify the controller.  
2. The PXU is an open-type device. Make sure it is installed in an enclosure free of dust and  
humidity in case of an electric shock.  
3. Wait for one minute after the power is switched off to allow the unit to discharge. DO NOT  
touch the internal wiring within this period of time.  
CONSTRUCTION  
DIMENSIONS In inches (mm) - 1/16 DIN  
PANEL CUT-OUT  
1.89  
0.26  
1.77  
(45.0)  
0.31  
(7.80)  
3.14 (79.70)  
(48.0)  
(6.70)  
1
2
3
4
5
6
7
8
0.47 (11.88)  
0.83 (21.0)  
13  
14  
15  
16  
17  
18  
1.89  
(48.0)  
9
1.77  
(45.0)  
10  
11  
12  
1

与PXU400C0相关器件

型号 品牌 获取价格 描述 数据表
PXU41A50 REDLION

获取价格

MODEL PXU - TEMPERATURE/PROCESS CONTROLLERS
PXU41AE0 REDLION

获取价格

MODEL PXU - TEMPERATURE/PROCESS CONTROLLERS
PXV1220S ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS
PXV1220S_1 ETC

获取价格

thermal sensitive chip attenuators.
PXV1220S-06DBN1-T ETC

获取价格

Temperature compensated chip attenuators
PXV1220S-10DBN1-T ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS
PXV1220S-10DBN2-T ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS
PXV1220S-10DBN3-T ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS
PXV1220S-10DBN4-T ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS
PXV1220S-10DBN5-T ETC

获取价格

P-V SERIES, THERMAL SENSITIVE CHIP ATTENUATORS