ALUMINUM ELECTROLYTIC CAPACITORS
®
PVH WITH CONDUCTIVE POLYMER SOLID ELECTROLYTE
$QWLꢁ
FOHDQLQJ
VROYHQW
*5((1
&$3
/RZ
(65
ꢂꢃꢄÝ&
ꢅꢃꢃꢃKRXUV
60'
&KLSꢀ7\SH
●
Super low E.S.R. and high ripple current are realized.
Guaranteed 105℃, 2000 hours.
●
PVH
Specifications
Item
Performance
Category temperature range (℃)
-55 to +105
±20
Tolerance at rated capacitance (%)
(20℃,120Hz)
Rated voltage (V)
Leakage current (µA)
2.5 to 20
Less than 0.2 CV
25,35
Less than 0.5 CV
Leakage current (µA)
*Note
C : Rated capacitance (µF) ; V : Rated voltage (V)
(20℃)
Tangent of loss angle (tanδ)
Less than 0.12
(20℃,120Hz)
Impedance ratio (max.)
Characteristics at high
and low temperature
Z-55℃/Z+20℃ : 1.50
(100kHz)
Test time
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
2000 hours
The initial specified value or less
Within 20% of initial value
150% or less of the initial specified value
200% or less of the initial specified value
Endurance (105℃)
(Applied ripple current)
±
Test time
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
500 hours
The initial specified value or less
Within ±20% of initial value
150% or less of the initial specified value
200% or less of the initial specified value
Damp heat, steady state
(humidity)
60℃, 90 to 95%RH
The capacitors shall be subject to 1000 cycles each consisting of charge with the surge voltage specified at 15 to 35℃ for 30 seconds
through a protective resister (Rc=1kΩ) in 6 minutes per cycle. Surge voltage : 1.15 times of rated voltage
Characteristics of applied
surge voltage
Leakage current
Percentage of capacitance change
Tangent of the loss angle
E.S.R. change
The initial specified value or less
Within 20% of initial value
150% or less of the initial specified value
200% or less of the initial specified value
±
Failure tare
0.5% per 1000 hours maximum (Confidence level 60% at 105℃)
Note : If any doubt arises, measure the leakage current after following voltage application treatment.
*
Voltage application treatment : DC rated voltage are applied to the capacitors for 120 minutes at 105℃.
Outline Drawing
Unit : mm
Part numbering system (example : 4V150µF)
0.3MAX
A±0.2
PVH
̶
4
V
151
M
F60 E ̶
Rated voltage
symbol
Rated capacitance
symbol
Capacitance
tolerance symbol
Casing
symbol
Taping
symbol
Series code
W
L±0.3
(
) : Reference size
φD
6.3
8
L
A
B
C
W
P
Casing symbol
F60
5.7
6.7
7.7
6.6
8.4
10.4
6.6
8.4
10.4
2.7
3.0
3.2
0.5 to 0.8
0.5 to 0.8
0.7 to 1.1
2.0
3.1
4.7
G70
H80
10
●
●
●
Soldering conditions are described on page 13.
Land pattern size are described on page 11.
The taping specifications are described on page 14.
NOTE
Design, Specifications are subject to change without notice.
34
CAT.No.2013/2014E