PT4100—24V
SLTS020A
(Revised 1/15/2001)
15 Watt Isolated DC-DC Converter
• Input Voltage Range:
18V to 40V
• 1500 VDC Isolation
• Low Profile
• Current Limit
• Short-Circuit Protection
• Over-Temperature Shutdown
• UL1950 recognized
• CSA 22.2 950 certified
• Meets EN60950
The PT4100—24V series of dc/dc
converters provide 18 Watts/in3 of isolated
power in a single low-profile module. De-
signed to operate from a standard 24V
telecom bus, these modules employ
switching frequencies of up to 850kHz,
planar magnetics, and surface-mount con-
struction. They are designed for Telecom,
Industrial, Computer, Medical, and other
distributed power applications that require
input-to-output isolation.
Specifications
Standard Application
PT4100—24V SERIES
Min Typ Max
Characteristics
(Ta=25°C unless noted)
On/Off
Symbols
Conditions
Units
1
Output Current
Io
Over Vin range,
Vo = 5V
0
0
0
—
3.0
+Vin
-Vin
+Vout
-Vout
3
2
5
4
Vo = 12V
Vo = 15V
—
—
1.25
1.0
A
PT4100
Current Limit
Icl
Vin = 18V,
Vo = 5V
Vo = 12V
Vo = 15V
—
—
—
4.0
1.75
1.4
—
—
—
A
On/Off Standby Current
Short Circuit Current
Iin standby
Isc
Vin = 24V, Pin 1 = -Vin
—
7
10
mA
A
Vin = 24V,
Vo = 5V
Vo = 12V
Vo = 15V
—
—
—
6.25
2.5
—
—
—
2.0
Pin-Out Information
Pin Function
Inrush Current
Iir
tir
Vin = 24V @ max Io
On start-up
—
—
1.0
1.0
2.0
5.0
A
mSec
Remote
ON/OFF
Input Voltage Range
Vin
Io = 0.1 to max Io
18.0
24.0
40.0
V
1
Output Voltage Tolerance ∆Vo
Over Vin Range
TA= -40°C to +85°C
—
±1.0
±2.0
%Vo
2
3
4
5
6
-Vin
+Vin
Line Regulation
Load Regulation
Vo Ripple/Noise
Regline
Over Vin range @ max Io
10% to 100% of Io max
—
—
±0.2
±0.4
±1.0
±1.0
%Vo
%Vo
Regload
Vn
-Vout
Vin=24V, Io=3.0A, Vo=5V
Vin=24V, Io=1.25A, Vo=12V
Vin=24V, Io=1.25A, Vo=15V
—
—
—
75
100
150
200
+Vout
75
mVpp
Do not connect
100
Transient Response
Efficiency
ttr
50% load change
—
—
125
3.0
200
5.0
µSec
%Vo
Vo over/undershoot
η
Vin=24V, Io=3.0A, Vo=5V
Vin=24V, Io=1.25A, Vo=12V
Vin=24V, Io=1A, Vo=15V
—
—
—
82
82
83
—
—
—
%
Ordering Information
Through-Hole
PT4104A = 5 Volts
PT4105A = 12 Volts
PT4106A = 15 Volts
Switching Frequency
ƒo
Over Vin and Io,
Vo=5V
Vo=12V/15V
800
600
850
650
900
700
kHz
°C
Recommended Operating Ta
Temperature Range
Vin = 24V @ max Io
-40
—
+85 (1)
Free air convection, (40-60LFM)
Free air convection, (40-60LFM)
@ Thermal shutdown
Thermal Resistance
Case Temperature
Storage Temperature
Mechanical Shock
θja
Tc
Ts
—
—
12
—
—
—
°C/W
°C
Surface Mount
—
100
110
PT4104C = 5 Volts
PT4105C = 12 Volts
PT4106C = 15 Volts
-40
°C
Per Mil-STD-202F, Method 213B,
6mS, Half-sine, mounted to a PCB
—
50
—
G’s
(For dimensions and PC
board layout, see Package
Style 710.)
Mechanical Vibration
Weight
—
—
Per Mil-STD-202F, Method 204D,
10-500Hz, Soldered in a PCB
—
—
10
28
—
—
G’s
—
grams
Isolation
—
—
—
—
—
—
1500
—
—
—
—
—
V
Capacitance
Resistance
1100
—
pF
MΩ
10
Flammability
—
Materials meet UL 94V-0
Referenced to –Vin
(2)
Remote On/Off
On
Off
2.5
0
7.0
0.8
V
Notes: (1) See thermal derating curves.
(2) If pin2 is left open, the converter will operate when input power is applied.
For technical support and more information, see inside back cover or visit www.ti.com/powertrends