44~49W AC-DC Dual Output Desktop
P50A-D series
Features :
3 pole AC inlet IEC320-C14
Class
power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: PWM 3882 circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
SPECIFICATION
ORDER NO.
P50A13-R1B
P50A14-R1B
P50A16-R1B
SAFETY MODEL NO.
DC VOLTAGE
PSU50A-13
Note.2 5V
PSU50A-14
5V
PSU50A-16
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
4A
2A
4A
1.8A
4A
1A
0.5 ~ 4.0A
44W
0.1 ~ 2.0A
0.5 ~ 4.0A
47W
0.1 ~1.8A
0.5 ~ 4.0A
49W
0.1 ~ 1.0A
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.4 6.0%
100mVp-p
50mVp-p
100mVp-p
50mVp-p
100mVp-p
OUTPUT
Fixed
10%
1.0%
9.0%
6.0%
1.0%
5.0%
10%
1.0%
9.0%
6.0%
1.0%
5.0%
10%
1.0%
9.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
70%
74%
75%
INPUT
1.6A / 100VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
40A / 230VAC
0.75mA / 240VAC
150 ~ 250% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
ENVIRONMENT
SAFETY &
5V: 110 ~ 140% of rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ +40 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
EMC
(Note. 7)
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
MTBF
280K hrs min. MIL-HDBK-217F (25
)
OTHERS
DIMENSION
PACKING
PLUG
147*76*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
CONNECTOR
CABLE
Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P50A-D-SPEC 2007-05-14