PSSEU61 SERIES
Up to 63 Watts, AC/DC Switching Power Supplies
Rev B
FEATURES
• Class I
• Output Voltage Available from 3VDC to 50VDC
• Single to Quad Outputs
• RoHS Compliant
• Internal EMI Filter
• Over Voltage Protection (Crowbar Design)
• Input Surge Current, Over Voltage, and Over Load Protection
• 2-Pin Input Connector
• Up to 63 Watts Output Power
• 100% Burn-in Tested
• Wide Input Voltage Range: 90~264VAC,
47~63Hz
• 3-Pin Input Connector Available (See PSSEU60 Series)
• Meets FCC Part-15 Class B and CISPR-22 Class B Emission
Limits
• UL/cUL(UL 60950-1:2nd Edition) Safety Approvals
DESCRIPTION
The PSSEU61 series of Class I AC/DC switching mode power supplies provides up to 63 Watts of continuous
output power in a 5.43” x 3.43” x 1.76” enclosed package. This series has single, dual, triple, and quad output
models with a wide input voltage range of 90~264VAC. These power supplies have an internal EMI filter and are
protected against over load, over voltage, and input surge current conditions. This series also has UL/cUL (UL
60950-1: 2nd edition) safety approvals and meets FCC Part-15 class B and CISPR-22 Class B emission limits.
These units are well suited for use in industrial equipment as well as many other applications. All models are
100% burn-in tested.
Size:
Weight:
5.43 x 3.43 x 1.76 inches 1.1 lbs (500g)
138.0 x 87.0 x 44.6 mm
TECHNICAL SPECIFICATIONS: PSSEU61 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
TEST CONDITIONS Min
SPECIFICATION
Typ
Max
Unit
INPUT SPECIFICATIONS
Safety Approvals Input Voltage Range
Operating Input Voltage Range
100
90
47
240
264
63
Input Voltage
Input Frequency
Input Current
VAC
Hz
A
100VAC, full load
240VAC, full load
1.6
1.0
115VAC, full load, 25°C, cold start
230VAC, full load, 25°C, cold start
33
65
5
Inrush Current
A
Single Output Models
Dual, Triple, & Quad Output Models
No Load Power Consumption
230VAC, no load
W
5.5
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Power
Output Current
See Table
See Table
LL to HL, full load
230VAC
0.5
3
1
7
63
%
%
W
Outputs under 3.3VDC
Others
2
1
Ripple & Noise (peak to peak)
90VAC, full load
%
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
PROTECTION
110VAC, full load
100VAC, full load
100VAC, Full load to half load
0~50°C
12
ms
s
ms
2
4
-0.04
+0.04
%/°C
Over Voltage Protection
Over Current Protection
GENERAL SPECIFICATIONS
Efficiency
112
110
132
150
%
%
230VAC, full load
Primary to Secondary
Primary to PE
Test Voltage = 500VDC
240VAC/60Hz
70
4242
2506
50
88
%
Dielectric Withstanding Voltage
VDC
Isolation Resistance
Leakage Current
MΩ
mA
0.75
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Derating linearly from 100% Load at 25°C to 50% load at 70°C
MIL-HDBK-217F, 25°C
0
-40
0
+70
+85
95
°C
°C
%
0
95
%
Cooling
MTBF
Free air convection
100,000
hours
PHYSICAL SPECIFICATIONS
Weight
1.1 lbs (500g)
Dimensions (L x W x H)
Input Connector
5.43 x 3.43 x 1.76 inches (138.0 x 87.0 x 44.6 mm)
See mechanical drawing
Output Connector
SAFETY & EMC
Safety Approvals
See mechanical drawing
UL/cUL (UL 60950-1: 2nd edition)(1)
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15 110VAC
220VAC
B
B
Class
Class
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
10/3/2019
Page 1 of 4