PSRL0603 Series
Single Output
Up to 250 Watts
AC/DC Switching Power Supply
FEATURES
● 2 Year Warranty
● Output Voltages from 2 ~ 60VDC
● AC Input Range Auto-Selectable
● Approved to UL CUL TUV CB and CE
● Power Factor Corrected to EN61000-3-2 Class A
● Providing Peak Power 600W within 500uS Duty Duration
● Low Leakage Current 500uA @ 240VAC / 300µA @ 120VAC
● U-Chassis & Enclosed with Built-in Fan Mechanical Options
● Smallest 250W with 1U Height Power Density: 10.4 Watts/cu in.
U Type: (U-Chassis): 5(L) x 3.2(W) x 1.5(H) inches.
F Type: (Enclosed with top built-in fan): 5(L) x 3.2(W) x 2(H) inches.
SPECIFICATIONS: PSRL0603 Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
Input Voltage
90 - 132 / 180 - 264 VAC, Auto-Selectable
Input Frequency
47 to 63Hz
Input Current
6 / 3A at 110 - 120 / 200 - 240 VAC.
Inrush Current
Leakage Current
Remote On-Off
Max. 70A @ 230VAC and 35A @ 115VAC; cold start.
Regular type 1.5mA @240VAC. (Optional for 500µA max. at 300VAC / 200µA max. at 120VAC input).
Designated as RMSW on the CN1, requires a low signal to inhibit output. Hiccough mode.
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Output Power Range
Output Adjustability
Total Regulation
250 Watts max with airflow. (See Notes 3 and 4)
Output user adjustable ±5% minimum.
±1%
See Table
Output Current
Ripple & Noise (peak to peak)
Transient Response
Hold-Up Time
±1%
Output voltage returns to within 1% in less than 2.5ms for a 50% load change, peak does not excess 5%.
20ms min. at 80% of full load.
Overshoot
Turn On Delay
PROTECTION
Turn-On & Off overshoot < 5% over nominal voltage.
1 second maximum at 120VAC.
Over Voltage Protection
Short Circuit Protection
Over-Temperature Protection
Over Power Protection
Input Fusing Protection
GENERAL SPECIFICATIONS
Switching Frequency
Efficiency
Unit latching down when output exceeds 130% and recycle AC input to reset.
Trip without damage and auto-recovery.
Unit protected of excessive operating ambient 85°C and automatic recovery.
Fold back mode 110-140%; Auto-recovery.
One T6A/250V fuse inserted in primary.
25KHz fixed frequency.
70% for 3.3V, 75% for 5V, 80% for 12V, and 83% min. for other outputs (Measuring at 230VAC and full load).
1500 VAC input line to chassis (10mA DC cut off current). 3000VAC primary to secondary windings and
1500VAC primary to core. All for 3 sec.
Withstand Voltage
Burn In
PFC
45 ±5°C for one hour @ 230VAC with full load.
Power factor corrected to EN61000-3-2 Class A.
Designated as PG on the CN1 will go high 100-500ms after regulation and goes low 1ms before loss of
Power Good
regulation.
Power Supply On
Grounding Test
Green LED designated as LED1 on the PCB.
Apply 25A from ground pin of the three prong plug to the far most earth. Max. allowable resistance is 0.1 ohm.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797