1500W Single Output with PFC Function
PSP-1500 series
Features :
AC input active surge current limiting
Built-in active PFC function
Protections:Short circuit/Over load/Over voltage/Over temperature
Built-in constant current limiting circuit
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
PSP-1500-5
PSP-1500-12
PSP-1500-13.5 PSP-1500-15
PSP-1500-24
PSP-1500-27
PSP-1500-48
DC VOLTAGE
5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD
217.5A
0 ~ 217.5A
1087.5W
1200W
100mVp-p
4.75 ~ 5.5V
6.0%
112.5A
0 ~ 112.5A
1350W
1500W
150mVp-p
10 ~ 13.2V
3.0%
100.5A
0 ~ 100.5A
1356.75W
1500W
150mVp-p
12 ~ 15V
2.0%
90A
56.4A
50.4A
28.5A
0 ~ 90A
1350W
1500W
150mVp-p
13.5 ~ 18V
2.0%
0 ~ 56.4A
1353.6W
1500W
150mVp-p
20 ~ 26.4V
1.0%
0 ~ 50.4A
1360.8W
1500W
150mVp-p
24 ~ 30V
1.0%
0 ~ 28.5A
1368W
1500W
200mVp-p
41 ~ 56V
1.0%
Note.4
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
OUTPUT
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1500ms, 50ms/230VAC at full load
24ms/230VAC at full load
HOLD TIME (Typ.)
VOLTAGE RANGE
176 ~ 264VAC
47 ~ 63Hz
248 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
0.96/230VAC at full load
INPUT
77%
84%
84%
84%
85%
85%
86%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
8.4A/230VAC
80A/230VAC
<3.5mA / 240VAC
LEAKAGE CURRENT
115 ~ 140% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1) Detect on the heatsink of PFC MOSFET 90 (TSW2) Detect the winding of output choke
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
OVER LOAD
57.6 ~ 67.2V
OVER VOLTAGE
PROTECTION
FUNCTION
OVER TEMPERATURE
REMOTE CONTROL
WORKING TEMP.
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
sink current <30mA
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ISOLATION RESISTANCE
SAFETY &
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 5)
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
EMS IMMUNITY
MTBF
43.4K hrs min. MIL-HDBK-217F (25
278*129*190.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
7.4Kg; 2pcs/15.5Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.