PSMG600 SERIES
600 Watts
Medical & ITE Enclosed AC/DC Supply
Single Outputs
Rev A
FEATURES
• Wide Operating Voltage 90~264VAC
• Input to Output: 2MOPP
• High ESD Immunity
• Active Power Factor Correction
• Over Voltage, Over Load, Over
Temperature, and Short Circuit Protection
• Optional 5V Standby Output & RS485 Communication
• IEC60601-1 Edition 3.1, ES60601-1:2005 (R2012),
CAN/CSAC22.2 No. 60601-1:14, EN60601-
1:2015/A1:2013, IEC62368-1 Edition 2.0, UL 62368-1,
CAN/CSA-C22.2 No. 62368-1-14, EN62368-1:2014
Safety Approvals
APPLICATIONS
• Test and Measurement
• Lab Equipment
• Ultrasound
• Video Wall Display
• Telecommunications
• In Vitro Diagnostic
Devices
DESCRIPTION
The PSMG600 series of AC/DC power supplies offers 600 watts of
output power in an 8.5” x 3.94” x 1.57” enclosed case. This series
consists of single output models with a wide operating voltage range
of 90~264VAC. Each model features active power factor correction,
high ESD immunity, and protection against over voltage, over load,
over temperature, and short circuit conditions. This series also has
IEC60601-1 Edition 3.1, ES60601-1:2005 (R2012), CAN/CSAC22.2
No. 60601-1:14, EN60601-1:2015/A1:2013, IEC62368-1 Edition 2.0,
UL 62368-1, CAN/CSA-C22.2 No. 62368-1-14, EN62368-1:2014
safety approvals.
Size: 8.5in x 3.94in x 1.57in
(225.5mm x 100mm x 40mm)
• Industrial Control and
Automation
• Medical Applications
MODEL SELECTION TABLE
Main Output Chart (Vo1)
Max Output Hold Up
Adjustment
Regulation Regulation
Vo1
Typ.
Efficiency
Typ. No Load
Consumption
Short Circuit
Protection
Model Number
Vo1
Io
Ripple Max
Power
600W
600W
590W
590W
590W
590W
Time
16ms
16ms
16ms
16ms
16ms
16ms
PSMG600-24S
PSMG600-48S
24VDC
48VDC
±2%
±2%
±3%
±2%
±3%
±2%
±3%
±2%
25.00A
240mVp-p
480mVp-p
240mVp-p
480mVp-p
240mVp-p
480mVp-p
89%
91%
<5W
Auto Recovery
Auto Recovery
Latch Off
12.50A
<5W
PSMG600-24SP 24VDC
PSMG600-48SP 48VDC
PSMG600-24SB 24VDC
PSMG600-48SB 48VDC
±2%
20.48A~24.58A
10.24A~12.29A
20.48A~24.58A
10.24A~12.29A
88.5%
90%
0.8 (Standby Mode)
0.8 (Standby Mode)
0.8 (Standby Mode)
0.8 (Standby Mode)
±2%
Latch Off
±20%
±20%
88.5%
90%
Latch Off
Latch Off
MODEL SELECTION TABLE
Standby Output Chart (Vo2)
Model Number
PSMG600-24SP
PSMG600-48SP
PSMG600-24SB
PSMG600-48SB
Vo2
Vo2 Regulation
Io Max
Remote On/Off Control
Positive Logic (3.3~5V)
Positive Logic (3.3~5V)
Positive Logic (3.3~5V)
Positive Logic (3.3~5V)
Short Circuit Protection
Auto Recovery
Ripple Max
5VDC
5VDC
5VDC
5VDC
±5%
±5%
±5%
±5%
2A
2A
2A
2A
60mV
60mV
60mV
60mV
Auto Recovery
Auto Recovery
Auto Recovery
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
6/28/2021
Page 1 of 6