PSMAY60 SERIES
60 Watts
Medical & Industrial AC/DC Module
Single Output
Rev B
PCB Mount
Chassis/DIN Rail Mount
FEATURES
• Universal Input of 85~264VAC
• Fully Encapsulated Plastic Case
• PCB, Chassis, and DIN-Rail Mounting
Packages Available
• Over Voltage, Over Load, and Short
Circuit Protection
• RoHS & REACH Compliant
• CE Marked
• Protection Class II per IEC/EN 60536
• Medical and Industrial Safety Approvals
DESCRIPTION
The PSMAY60 series of medical and industrial AC/DC power modules offers 60 watts of
output power in a compact PCB, Chassis Mount, or DIN Rail mount package. This series
consists of single output models with a universal input range of 85~264VAC in a fully
encapsulated plastic case. Each model in this series has over voltage, over load, and short
circuit protection, is RoHS & REACH compliant, and has medical and industrial safety
approvals.
Size: 3.50 x 2.66 x 1.35in Size: 4.41 x 2.67 x 1.50in
MODEL SELECTION TABLE
Input Current
Maximum
Capacitive Load
Model Number(2) Input Voltage Range Output Voltage Output Current
Efficiency Output Power
115VAC, 60Hz 230VAC, 50Hz
PSMAY60-S051
PSMAY60-S12
PSMAY60-S15
PSMAY60-S24
PSMAY60-S48
5.1VDC
12VDC
15VDC
24VDC
48VDC
10000mA
5000mA
4000mA
2500mA
1250mA
880mA
1000mA
1000mA
1000mA
988mA
528mA
600mA
600mA
600mA
593mA
8000µF
3900µF
3300µF
1500µF
680µF
84%
87%
85~264VAC
(120~370VDC)
87%
87%
88%
60 Watts
SPECIFICATIONS
All specifications typical at 25ºC, resistive load, 115VAC, 60Hz Input Voltage, after warm-up time rated output current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
AC Range
DC Range
85
120
47
264
370
440
30
VAC
VDC
Hz
Input Voltage Range
Input Frequency
Inrush Current
@115VAC, Cold Start @25ºC
@230VAC, Cold Start @25ºC
A
60
No Load Power Consumption
Leakage Current
0.5
W
µA
80
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Voltage Accuracy
Line Regulation
Load Regulation
No Load Power Consumption
Output Power
±1.0
±0.2
±0.5
±2.0
±1.0
±1.0
0.5
%Vnom.
Vin=Min. to Max. @Full Load
Io=0% to 100%
%
%
W
See Table
See Table
Output Current
Minimum Load
Maximum Capacitive Load
No Minimum Load Requirement
See Table
5.1VDC Models
Other Output Models
2.0
1.0
3.0
1.5
5
%Vpp of
Ripple & Noise (20MHz bandwidth)(3)
Vo
%
Overshoot
@115VAC, 60Hz
@230VAC, 50Hz
20
80
Hold-Up Time
Ms
Temperature Coefficient
PROTECTION
±0.02
%/ºC
Short Circuit Protection
Over Load Protection(4)
Over Voltage Protection
Hiccup Mode, Automatic Recovery
105 %Inom.
85VAC, Hiccup Mode, Automatic Recovery
Zener Diode Clamp
120
% of Vo
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
10/25/2022
Page 1 of 5