5W Single Output DC-DC Converter
PSD-05 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fix switching frequency at 67KHz
Low cost
High reliability
2 years warranty
SPECIFICATION
MODEL
PSD-05-05
PSD-05-12
PSD-05-24
5V
DC VOLTAGE
12V
24V
1A
0.45A
0.22A
RATED CURRENT
0 ~ 1A
5W
0 ~ 0.5A
5.4W
0 ~ 0.25A
5.28W
CURRENT RANGE
RATED POWER
50mVp-p
RIPPLE & NOISE (max.) Note.2
100mVp-p
2.0%
OUTPUT
150mVp-p
2.0%
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
1.0%
1.2s, 20ms,--- at full load
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
36 ~ 72VDC
75%
78%
78%
EFFICIENCY(Typ.)
INPUT
0.15A/48V
DC CURRENT(Typ.)
Above 105% rated output power
OVERLOAD
Protection type : Fold back current limiting, recovery automatically after fault condition is removed
13.8~16.2V
5.75~ 6.75V
27.6~ 32.4V
OVER VOLTAGE
OVER TEMPERATURE
PROTECTION
Protection type : Hiccup mode, recovery automatically after fault condition is removed
U1 Tj140 typically(U1)detect on main control IC
æ
Protection type : Hiccup mode, recovery automatically after temperature goes down
¡
æ
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.05%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:2KVAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
SAFETY &
EMC
EMI CONDUCTION & RADIATION
Compliance to EN61000-4-2, 3, 4, 6, 8 ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
EMS IMMUNITY
DIMENSION
PACKING
75*40*20mm (L*W*H)
OTHERS
NOTE
50mg;120pcs/6.25Kg/1CUFT
1. All parameters NOT specially mentioned are measured at 48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it
still meets EMC directives.
File Name:PSD-05-SPEC 2009-04-21