APPLICABLE STANDARD
Operating
UL,C-UL STANDARD:E52653、TUV STANDARD:E50256466 (Appendix 1)
-40 ℃ to +105 ℃(Note 1)
Storage temperature
range
(Included temperature rise
caused by current-carrying)
-40 ℃ to +60 ℃(Note 2)
temperature range
Power:150A(UL,C-UL,TUV) (Appendix 1)
:210A(Derating curve:25℃)
(Appendix 2)
Voltage
Power: (Appendix 1)
RATING
Current
14sq to 50sq
Applicable wire
※The Rating Current for each applicable wire
size can be found in table 3.
(AWG#5 to AWG#1/0)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT
AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
x x
x x
Marking
ELECTRICAL CHARACTEREISTICS
Contact Resistance
DC 1 A
0.3 mΩ MAX.
x x
Insulation Resistance
Voltage Proof
250 V DC
5000 MΩ MIN.
x -
2000 V AC. for 1 min.
No flashover or breakdown.
x x
MECHANICAL CHARACTERISTICS
Mating and Unmating Forces Measured by applicable connector at a speed of
Mating force : 98 N MAX.
Unmating force : 98 N MAX.
x -
x -
x -
30 mm 3 mm/min.
Mechanical Operation
Vibration
100 times insertions and extractions at a speed of 600
times/hour.
① Contact resistance change: 0.5 mΩ MAX.
② No damage, crack and looseness of parts.
Frequency : 10 to 55 Hz, singe amplitude 0.75 mm,
① No electrical discontinuity of 10 μs.
② No damage, crack and looseness of parts.
x -
at 5 min/cycle, 10 cycles each in 3 axial directions.
30 cycles in total.
Shock
490 m/s2 duration of pulse 11 ms for 3 times
x -
x -
in 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Temperature -40 → 105 ℃
① Contact resistance change:0.5 mΩ MAX.
Time 30 → 30 min
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
Rapid Change of Temperature Chamber transfer time is 2 to 3 min.
Conduct 5 cycles of above cycles(mated)
and exposed in the room temperature for 1 to 2 hours.
After exposure at temperature 402 C, humidity 90 to
95 ,for 96 h.(mated), exposed at room temperatrure
for 1 to 2 hour.
Humidity Life
① Contact resistance change:0.5 mΩ MAX.
x -
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
After exposure at temperature 1052 C,
humidity for 96 h(mated), exposed at room temperatrure
for 1 to 2 hour.
Heat Resistance
① Contact resistance change: 0.5 mΩ MAX.
x -
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
TU.TANIGUCHI
KG.OKITA
20230130
20230130
20230127
20230127
MO.SHIMOYAMA
MO.SHIMOYAMA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-128047-11-00
PS3-2US(11)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
PART NO.
CODE NO
CL0236-1041-0-11
1/9