APPLICABLE STANDARD
Operating
-40 ℃ TO +105 ℃(Note 1)
(Included temperature rise
caused by current-carrying)
Power: 1000 V
Storage Temperature
Range
-40 ℃ TO +60 ℃(Note 2)
Power: 150A
Temperature Range
Voltage
RATING
Signal: AC,DC 250 V
: 210A(Derating curve:25℃)
(Appendix 1)
Current
Signal: 1A
14sq to 50sq
Applicable Wire
※The Rating Current for each applicable wire
(AWG#5 to AWG#1/0)
size can be found in table 3.
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT
AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
x x
x x
Marking
ELECTRICAL CHARACTEREISTICS
Contact Resistance
Power: DC 1 A
Power: 0.3 mΩ MAX.
x x
Signal: 60 mΩ MAX. (Note 3)
(Assurance test is only signal)
5000 MΩ MIN.
Signal: 100 mA(DC OR 1000Hz)MAX.
250 V DC
Insulation Resistance
Voltage Proof
x -
Power: 2000 V AC. for 1 min.
Signal: 650 V AC. for 1 min.
No flashover or breakdown.
x x
(Assurance test is only signal)
MECHANICAL CHARACTERISTICS
Mating and Unmating Forces Measured by applicable connector at a speed of
Mating force: 137.2 N MAX.
Unmating force: 137.2 N MAX.
x -
x -
x -
30 mm 3 mm/min.
Mechanical Operation
100 times insertions and extractions at a speed of 600
times/hour.
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
(GT8E of signal part: 30 times insertions and
extractions)
② No damage, crack and looseness of parts.
Vibration
Shock
Frequency: 10 to 55 Hz, singe amplitude 0.75 mm,
① No electrical discontinuity of 10 μs.
② No damage, crack and looseness of parts.
x -
at 5 min/cycle, 10 cycles each in 3 axial directions.
30 cycles in total.
490 m/s2 duration of pulse 11 ms for 3 times
x -
x -
in 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Temperature -40 → 105 ℃
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
Time 30 → 30 min
Rapid Change of Temperature Chamber transfer time is 2 to 3 min.
Conduct 5 cycles of above cycles(mated)
② Insulation resistance: 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
and exposed in the room temperature for 1 to 2 hours.
After exposure at temperature 402 C, humidity 90 to
95 , for 96 h (mated), exposed at room temperatrure
for 1 to 2 hour.
Humidity Life
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
x -
② Insulation resistance: 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
After exposure at temperature 1052 C,
humidity for 96 h (mated), exposed at room
temperatrure for 1 to 2 hour.
Heat Resistance
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
x -
② Insulation resistance: 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
TA.TORIHARA
CHECKED
AH.KODAMA
RI.TAKAYASU
DATE
1
1
REMARK
DIS-E-00000869
17.04.14
15.12.244
△
APPROVED
CHECKED
DESIGNED
DRAWN
(Note 1) The operation temperature includes the temperature rise by current carrying.
(Note 2) Storage temperature range shows storage condition for unused
products including packing materials. Follow the operating
NM.NISHIMATSU
WR.YAMADA
15.12.244
15.12.222
15.12.22
temperature range for storage condition after mounting.
(Note 3) Contact resitance of signal parts are the value that contains GT8E connector.
WR.YAMADA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129146-00-00
SPECIFICATION SHEET
PART NO.
CODE NO
PS3-2UP/12P/16P-FA
CL236-1080-0-00
HIROSE ELECTRIC CO., LTD.
1/7
1
△
FORM HD0011-2-1
1
△
DIS-E-00000869 Inscription changes regarding Rating Current and others.