APPLICABLE STANDARD
OPERATING
STORAGE
2 -55C TO +85C
1 -55C TO +105C
TEMPERATURE RANGE
VOLTAGE
TEMPERATURE RANGE
AC 600 V , DC 600 V
―
―
PQ50B CONTACT:
PQ50B CONTACT:
30A/PIN (AWG#10 UL1015)
PQ50(A) CONTACT:
AWG#10 TO AWG#12(UL-STYLE:UL1015)
PQ50(A) CONTACT:
RATING
19A/PIN (AWG#14 UL1015)
PQ50S(A) CONTACT:
AWG#14 TO AWG#22
CURRENT
APPLICABLE CABLE
(UL-STYLE:UL1007,UL1015)
PQ50S(A) CONTACT:
12.5A/PIN (AWG#18 UL1007)
CONDUCT SPECIFIED CURRENT TO
A SINGLE PIN OF CONTACTS.
AWG#18 TO AWG#28
(UL-STYLE:UL1007)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRICAL CHARACTERISTICS
X
X
X
X
-
-
-
-
3
3
5 m MAX. (CONTACT SPACING)
50 m MAX. (SHELL SPACING)
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz) MAX.
5000 M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
500 V DC.
3310 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
TEMPERATURE RISE
CONDUCT SPECIFIED CURRENT TO A SINGLE PIN OF
BELOW CONTACTS.
PQ50B CONTACT ⇔ PQ50(A) CONTACT × 2PIN
(AWG#10 UL1015)
(AWG#14 UL1015)
X
-
CURRENT CARRIED:30A/PIN
MAX.30℃ INCREASE FROM AMBIENT TEMPERATURE.
PQ50(A) CONTACT ⇔ PQ50(A) CONTACT
(AWG#14 UL1015)
(AWG#14 UL1015)
CURRENT CARRIED:19A/PIN
PQ50S(A) CONTACT ⇔ PQ50S(A) CONTACT
(AWG#18 UL1007)
(AWG#18 UL1007)
CURRENT CARRIED:12.5A/PIN
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
①INSERTION FORCE : 6.0 N MAX.
WITHDRAWAL FORCE : 1.5 N MIN.
SPECIFICATION OF SINGLE SIDE OF
PQ50B CONTACT.
MEASURE WITH THE BELOW CONTACT PAIR.
①
②
③
PQ50B CONTACT
⇔ PQ50(A) CONTACT
X
-
PQ50(A) CONTACT ⇔ PQ50(A) CONTACT
PQ50S(A) CONTACT ⇔ PQ50S(A) CONTACT
②INSERTION FORCE : 3.0 N MAX.
WITHDRAWAL FORCE : 1.0 N MIN.
③INSERTION FORCE : 3.0 N MAX.
WITHDRAWAL FORCE : 0.3 N MIN.
INSERTION FORCE : 392 N MAX.
WITHDRAWAL FORCE : 72 N MIN.
MEASURE WITH THE LOOK LEVER RELEASED
(72 CONTACTS OF PQ50(A) ARE ASSEMBLED)
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
X
X
-
-
USE 6 UNITS OF PQ50WT-12P-UNIT AND PQ50WT-12S-UNIT.
APPLY SPECIFICATIONED PULL FORCE FOR A MINUTE FROM ① CONTACTS SHOULD BE RETAINED.
CABLE ASSEMBLY SIDE. ② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
PQ50B -1012SCFA(AWG#10)
CONTACT(LANCE)
:98.0 N
PQ50(A) -15P(S)CFA(AWG#14) :68.6 N
PQ50S(A) -1822P(S)CFA(AWG#18):29.4 N
RETENTION FORCES
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
RI.TAKAYASU
NM.NISHIMATSU
TY.MIURA
16.06.07
16.06.06
16.06.06
16.06.06
ABOVE SPESIFICATION SHOWS THE VALUES IN ASSEMBLED CONDITION WITH
APPLICABLE CRIMP CONTACTS.
Unless otherwise specified, refer to IEC 60512.
TY.MIURA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129307-00-00
PQWT-CM(35.5)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/3
CL236-2102-0-00
FORM HD0011-2-1