VAPPLICABLE STANDARD
OPERATING
STORAGE
2 -55C TO +85C
1 -55C TO +105C
TEMPERATURE RANGE
TEMPERATURE RANGE
AC 600 V ,DC 600 V(ONLY CONNECTOR)
VOLTAGE
―
―
AC 300 V ,DC 300 V(TUV・UL)
PQ50(A) CONTACT:
・PQ50WA/S-10*/34*-UNIT
RATING
19.0A/PIN (AWG#14)
AWG#14 TO AWG#22 (ONLY 10PIN)
(UL-STYLE:UL1007,UL1015)
PQ50S(A) CONTACT:
CURRENT
12.5A/PIN (AWG#16 UL1007)
12.5A/PIN (AWG#18 UL1007)
CONDUCT SPECIFIED CURRENT TO
A SINGLE PIN OF CONTACTS.
APPLICABLE CABLE
・OTHERS
AWG#16 TO AWG#28
(UL-STYLE:UL1007)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
MARKING
ELECTRICAL CHARACTERISTICS
X
X
X
-
-
-
3
3
5 m MAX. (CONTACT SPACING)
50 m MAX. (SHELL SPACING)
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz) MAX.
5000 M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
500 V DC.
X
-
3310 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
TEMPERATURE RISE
CONDUCT SPECIFIED CURRENT TO A SINGLE PIN OF
BELOW CONTACTS.
PQ50(A) CONTACT ⇔ PQ50(A) CONTACT
MAX.30℃ INCREASE FROM AMBIENT TEMPERATURE.
(AWG#14 UL1015)
(AWG#14 UL1015)
X
-
CURRENT CARRIED:19A/PIN
PQ50S(A) CONTACT ⇔ PQ50S(A) CONTACT
(AWG#18 UL1007)
(AWG#18 UL1007)
CURRENT CARRIED:12.5A/PIN
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
①INSERTION FORCE : 3.0 N MAX.
WITHDRAWAL FORCE : 1.0 N MIN.
②INSERTION FORCE : 3.0 N MAX.
WITHDRAWAL FORCE : 0.3 N MIN.
MEASURE WITH THE BELOW CONTACT PAIR.
X
X
X
-
-
-
①
②
PQ50(A) CONTACT ⇔ PQ50(A) CONTACT
PQ50S(A) CONTACT ⇔ PQ50S(A) CONTACT
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURE WITH THE LOOK LEVER RELEASED
(ALL CONTACTS ARE ASSEMBLED)
INSERTION FORCE : 270 N MAX.
WITHDRAWAL FORCE : 34 N MIN.
USE 2 UNITS OF PQ50WA/S-10*/34*-UNIT
AND PQ50WASX-46*-UNIT.
① CONTACTS SHOULD BE RETAINED.
APPLY SPECIFICATIONED PULL FORCE FOR A MINUTE FROM
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
CONTACT(LANCE)
CABLE ASSEMBLY SIDE.
① PQ50(A) -15P(S)CFA(AWG#14) :68.6 N
RETENTION FORCES
② PQ50S(A) -1822P(S)CFA(AWG#18):29.4 N
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
RI.TAKAYASU
NM.NISHIMATSU
TY.MIURA
16.06.03
16.06.03
16.06.03
16.06.03
ABOVE SPESIFICATION SHOWS THE VALUES IN ASSEMBLED CONDITION WITH
APPLICABLE CRIMP CONTACTS.
TY.MIURA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129060-00-00
PQ50WASX-46S-UNIT
PART NO.
CODE NO.
SPECIFICATION SHEET
0
△
1/3
HIROSE ELECTRIC CO., LTD.
CL236-2086-0-00
FORM HD0011-2-1