APPLICABLE STANDARD
OPERATING
STORAGE
2
-55C TO +85C
1
-40C TO +105C
TEMPERATURE RANGE
TEMPERATURE RANGE
VOLTAGE
RATING
300 V AC , 300 V DC
―
―
※ 5 A / PIN
AWG#24 TO AWG#28
CURRENT
※ Varies based on current-carrying APPLICABLE CABLE
(UL-STYLE : UL1007)
capacity of cable.
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
X
X
X
X
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRICAL CHARACTERISTICS
X
X
X
X
-
-
-
-
3
3
5 m MAX. (CONTACT SPACING)
40 m MAX. (SHELL SPACING)
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz) MAX.
5000 M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
500 V DC.
2200 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
INSERTION FORCE : 3
N MAX.
X
X
-
-
APPRICABLE CONTACT.
WITHDRAWAL FORCES
WITHDRAWAL FORCE : 0.3 N MIN.
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
INSERTION FORCE : 98
N MAX.
APPRICABLE CONNECTOR.
WITHDRAWAL FORCE : 14.7 N MIN.
29.4N MIN
APPLY AXIAL PULL OUT FORCE AT THE SPEED
RATE OF 25mm/min TO THE TERMINAL, AND MEASURE
THE FORCE WHEN THE TERMINAL IS PULL OUT.
CONTACT(LANCE)
X
-
RETENTION FORCES
CRIMP THE CABLE ONLY AT THE CONDUCTOR, AND RETENTION ① AWG#24 :
FORCE SHALL EXCEED THE SPECIFICATION WHEN PULL FORCE IS ② AWG#26 :
22.3 N MIN.
13.4 N MIN.
8.9 N MIN.
CONDUCTOR PRESSURE BONDING
FORCES
X
X
X
-
-
-
APPLIED.
③ AWG#28 :
APPLY PULL FORCE OF 98 N IN MATING DIRECTION FOR A ① CONTACTS SHOULD BE RETAINED.
CABLE CLAMP STRENGTH
MECHANICAL OPERATION
MINUTE.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
3
① CHANGE IN CONTACT RESISTANCE OF
CONTACTS : 10 m MAX.
500 TIMES INSERTIONS AND EXTRACTIONS.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
FREQUENCY : 10 TO 55 Hz, SINGE AMPLITUDE 0.75 mm,
AT 2 h, FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
X
X
-
-
VIBRATION
SHOCK
(REFERENCE FOR APPENDED FIGURE)
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
IN OPPOSITE DIRECTIONS OF EACH 6 DIMENSION AXIS FOR
3 TIMES AT 490 m/s2 DURACTIONS OF PULSE 11 ms.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
ABOVE SPECIFICATION SHOWS THE VALUES IN ASSEMBLED CONDITION WITH
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
KG.OKITA
20211222
20211221
20211221
20211221
APPLICABLE CRIMP CONTACTS.
HY.MATSUDA
HY.MATSUDA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-397158-00-00
PQ50S2-2428PCFA
SPECIFICATION SHEET
0
1/3
HIROSE ELECTRIC CO., LTD.
CL0236-0038-0-00
△
FORM HD0011-2-1