APPLICABLE STANDARD
OPERATING
STORAGE
1 -40℃ TO +105℃
2 -55℃ TO +85℃
TEMPERATURE RANGE
TEMPERATURE RANGE
RATING
VOLTAGE
AC 300 V , DC 300 V
―
―
AWG#16 TO AWG#18
(UL-STYLE : UL1007)
CURRENT
AWG#16・AWG#18(UL1007):12.5 A/PIN
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRICAL CHARACTERISTICS
X
X
X
X
-
-
-
-
3
3
5 mΩ MAX. (CONTACT SPACING)
40 mΩ MAX. (SHELL SPACING)
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz) MAX.
INSULATION RESISTANCE
VOLTAGE PROOF
500 V DC.
5000 MΩ MIN.
2200 V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
INSERTION FORCE : 3
N MAX.
X
X
-
-
APPRICABLE CONTACT.
WITHDRAWAL FORCES
WITHDRAWAL FORCE : 0.3 N MIN.
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
INSERTION FORCE : 98
N MAX.
APPRICABLE CONNECTOR.
WITHDRAWAL FORCE : 14.7 N MIN.
29.4N MIN
APPLY AXIAL PULL OUT FORCE AT THE SPEED
RATE OF 25mm/min TO THE TERMINAL, AND MESURE
THE FORCE WHEN THE TERMINAL IS PULL OUT.
CRIMP THE CABLE ONLY AT THE CONDUCTOR, AND RETENTION
FORCE SHALL EXCEED THE SPECIFICATION WHEN PULL FORCE IS
APPLIED.
CONTACT(LANCE)
X
-
RETENTION FORCES
CONDUCTOR PRESSURE BONDING
FORCES
① AWG#16 : 133.5 N MIN.
X
X
X
-
-
-
② AWG#18 :
89.0 N MIN.
APPLY PULL FORCE OF 98 N IN MATING DIRECTION FOR A ① CONTACTS SHOULD BE RETAINED.
CABLE CLAMP STRENGTH
MECHANICAL OPERATION
MINUTE.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
3
① CHANGE IN CONTACT RESISTANCE OF
CONTACTS : 10 mΩ MAX.
500 TIMES INSERTIONS AND EXTRACTIONS.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
FREQUENCY : 10 TO 55 Hz, SINGE AMPLITUDE 0.75 mm,
AT 2 h, FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 10 μs.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
X
X
-
-
VIBRATION
SHOCK
(REFERENCE FOR APPENDED FIGURE)
IN OPPOSITE DIRECTIONS OF EACH 6 DIMENSION AXIS FOR
3 TIMES AT 490 m/s2 DURACTIONS OF PULSE 11 ms.
① NO ELECTRICAL DISCONTINUITY OF 10 μs.
② NO DAMAGE. CRACK AND LOOSENESS OF PARTS.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
DIS-A-00063387
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
KG.OKITA
20211224
20211224
20211224
20211224
ABOVE SPESIFICATION SHOWS THE VALUES IN ASSEMBLED CONDITION WITH
APPLICABLE CRIMP CONTACTS.
HY.MATSUDA
YK.MORIYAMA
Unless otherwise specified, refer to IEC 60512
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-397341-00-00
PART NO.
CODE NO.
PQ50S2-1618SCFA
SPECIFICATION SHEET
0
△
1/3
HIROSE ELECTRIC CO., LTD.
CL0236-0042-0-00
FORM HD0011-2-1