PQ24050QEx40
18-36 V
50V
5V
200W
Max Power
2250V dc
Quarter-brick
DC-DC Converter
Input
Transient Input Output
Isolation
The PQ24050QEx40 PowerQor Exa Quarter-brick
converter is a next-generation, board-mountable,
isolated, fixed switching frequency DC-DC converter.
The Exa series offers industry leading power density
for standard isolated DC-DC converters with both a
wide input range and a tightly regulated output. This
module supplies an isolated step down voltage from
18-36 V to 5V and provides more available power
and higher efficiency than competitive converters.
This converter is available in openframe and encased
versions. RoHS Compliant (see last page).
Protection Features
• Input under-voltage lockout disables converter at low Vin conditions
• Output current limit
• Short circuit protection
• Protection from permanent damage and hazardous conditions
• Active back bias limit
PQ24050QEx40 Model
• Smooth startup with external load induced pre-bias
• Auto-recovery output OVP protects load from damaging voltages
• Thermal shutdown protects converter from abnormal conditions
Operational Features
• High efficiency, 94% at half rated load current
• Delivers 40A full power with minimal derating - no heatsink required
• Operating input voltage range: 18-36 V
Mechanical Features
• Input voltage transient capability: 50V, 1,000ms
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
• Industry standard quarter-brick pin-out
• Open Frame Size: 1.45" x 2.30" x 0.421" (36.8 x 58.4 x 10.7mm)
• Flanged pins designed to permit surface mount soldering,
avoid wave solder using FPiP technique on open frame units
• Encased Size: 1.536" x 2.386" x 0.500" (39.01 x 60.60 x 12.70 mm)
• Wide output voltage Trim range (-50% to +10%), see trim section
• Encased weight: 3.0 oz (85 g)
Control Features
• On/Off control referenced to input side
• Options
Contents
Page No.
Mechanical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Standards & Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Technical Figures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Applications Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Safety Features
Pending
• UL 60950-1:2007
• EN60950-1/A11:2009/A1:2010
Product # PQ24050QEx40
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006368 Rev. 1
01/31/13