NOTES:
REVISION X
C
1.
REPRESENTS A CRITICAL DIMENSION.
PMSDX-XX-XXXX-XX-XX.XX-X-XXX
2. BURR ALLOWANCE: .003[.08] MAX.
3. PARTS TO BE MOLDED TO POSITION.
FEP CABLE OPTION
OPTION
4. MINIMUM PIN PULLOUT FORCE: 5.000LB[22.24N].
5. CONTACT MUST BE INSERTED UNTIL RETENTION FEATURE LOCKS INTO PLACE.
6. ALL FINISHED GOODS ARE TO BE LAYER PACKAGED IN SHIPPING.
7. ONLY AVAILABLE IN TIN PLATING.
-T: FEP
(LEAVE BLANK FOR STANDARD
PVC INSULATION)
SINGLE
-M: METAL LATCH (USE IPBD-XX-D-M)
(LEAVE BLANK FOR PLASTIC)
C
8. ALL PARTS TO PASS ELECTRICAL TEST UPON ASSEMBLY
(INCLUDING HI-POT TEST AT 1000 VOLTS DC). AFTER FINAL ELECTRICAL TEST,
LABEL EACH ASSEMBLY WITH 1 LABEL-ET.
No OF POSITIONS
-02 THRU -15
X
DOUBLE
(PER ROW)
9. APPLICATIONS INVOLVING SEVERE BENDING REQUIRE 6" MINIMUM CABLE LENGTH.
10. DELETED.
-LUS: PLASTIC LATCH UP, STRAIGHT
-LDS: PLASTIC LATCH DOWN, STRAIGHT
-LUX: PLASTIC LATCH UP, CROSSED
-LDX: PLASTIC LATCH DOWN, CROSSED
-MUS: METAL LATCH UP, STRAIGHT
-MDS: METAL LATCH DOWN, STRAIGHT
-MUX: METAL LATCH UP, CROSSED
-MDX: METAL LATCH DOWN, CROSSED
WIRE GAUGE (AWG)
PVC: -16, -18, -206, -203, -22, -24
FEP: -18, -24
11. DELETED.
12. -203 USES 20 GAGE 300 VOLT CABLE.
13. AVAILABLE ONLY AS AN ASO.
14. -206 USES 20 GAGE 600 VOLT CABLE.
COLOR CODE
C
15. MINIMUM METAL LATCH RETENTION FORCE: 1.000LB[4.45N].
16. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,
TOLERANCES, TOOLING AND ITS REQUIREMENTS
17. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL
BE ±.125[3.18]. FOR OTHER LENGTHS, TOLERANCES SHALL BE ±2%.
18. AVAILABLE TO EXISTING CUSTOMERS ONLY, DO NOT DESIGN AS OF REVISION P.
LEAVE BLANK FOR ALL BLACK WIRE
C: COLOR CODED WIRE, SEE COLOR
SEQUENCE TABLE, SHEET 3
X
(NOT AVAILABLE WITH FEP OPTION)
END OPTION
-S: SINGLE END
LEAD STYLE
-D: DOUBLE END
-SP: STANDARD POWER (C-169-XX-SP-T)
-HP: HIGH POWER (C-169-XX-HP-T)
(SEE NOTE 18)
(MUST CHOOSE LUS, LDS, LUX, LDX,
MUS, MDS, MUX, OR MDX)
(No OF POS x .165[4.19])
+ .040[1.02]) REF
02
01
06
ASSEMBLED LENGTH
.478 12.14
REF
SPECIFY IN INCHES
.378 9.60 REF
3.00 INCHES MINIMUM FOR SINGLE ENDED
3.50 INCHES MINIMUM FOR DOUBLE ENDED
[USE DWCX-XX-XX-XXX]
DO NOT
SCALE FROM
THIS PRINT
N
(SEE TABLE 2)
IPBD-XX-D
"A"
DWCX-XX-XX-XXX
.776 19.71
REF
.485 12.32
REF
C
XX.XX
(SEE NOTE 17)
C
DWCX-XX-XX-XXX
XX.XX
(SEE NOTE 17)
X
FIG. 2
(PMSDX-05-XX-XX-XX.XX-D-LUS SHOWN)
(SAME AS FIG. 1, UNLESS OTHERWISE STATED)
FIG. 1
"A"
SECTION "A"-"A"
(PMSDX-05-XX-XX-XX.XX-S SHOWN)
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
.XX: .01 [.3]
2
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XXX: .005 [.13]
.XXXX: .0020 [.051]
SHEET SCALE: 1:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
* SEE NOTES 12 & 13
** SEE NOTE 14
.165[4.19] SOCKET DISCREET CABLE ASSEMBLY
DWG. NO.
HOUSING: VALOX 457, COLOR: NATURAL
CONTACT: PHOS BRONZE
CABLE; INSULATION: SEE CALLOUT
PMSDX-XX-XXXX-XX-XX.XX-X-XXX
WIRE: SEE CALE PRINT (NOT LEAD FREE)
METAL LATCH: NICKEL-PLATED BeCu, #25, 1/2 HT
F:\DWG\MISC\MKTG\PMSDX-XX-XXXX-XX-XX.XX-X-XXX-MKT.SLDDRW
BY:
DEAN P
07/28/2004 SHEET 1 OF 3