5秒后页面跳转
PM9607AP PDF预览

PM9607AP

更新时间: 2024-02-01 14:36:56
品牌 Logo 应用领域
SAMES /
页数 文件大小 规格书
16页 368K
描述
Energy Meter Evaluation Module

PM9607AP 数据手册

 浏览型号PM9607AP的Datasheet PDF文件第2页浏览型号PM9607AP的Datasheet PDF文件第3页浏览型号PM9607AP的Datasheet PDF文件第4页浏览型号PM9607AP的Datasheet PDF文件第5页浏览型号PM9607AP的Datasheet PDF文件第6页浏览型号PM9607AP的Datasheet PDF文件第7页 
Application Note:  
Energy Meter Evaluation Module  
PM9607AP  
sames  
INTRODUCTION  
This Application Note describes the functionality of the  
SA9607M and the SA9607P metering integrated circuits using  
the PM9607AP evaluation module. The SA9607 family is a low  
cost solution specifically designed to meet the needs of  
markets that require both live and neutral energy  
measurement, in order to detect possible meter tampering.  
Using the SA9607 family the meter manufacturer is able to  
build a meter that measures the energy consumption, even  
during a tamper condition, and records it to a mechanical  
counter.  
meter configurations possible with the SA9607M using the  
PM9607AP module. Note that the values of the current  
transformer’s resistor values need to change to make some of  
the rated conditions possible. This will be covered in the  
Analog Section.  
Setting  
Pin Status  
20A / 230V  
40A / 230V  
60A / 230V  
1 pulse / kWh  
10 pulse / kWh  
100 pulse / kWh  
RATED = 0  
RATED = Open  
RATED = 1  
MP1 = 0, MP0 = 0  
MP1 = 0, MP0 = 1  
MP1 = 1, MP0 = 0  
This application note will focus on the practical use of the  
SA9607 family. More detailed information specific to the  
SA9607M or SA9607P can be found in the applicable  
datasheet.  
Table 1: A summary of the pin settings possible with the  
SA9607M. Pin status 0 indicates connects to VSS and 1  
indicates connection to VDD  
THE SA9607 SERIES ENERGY METER ICS  
The SA9607 family is characterized by its ability to measure  
live and neutral power consumption simultaneously.  
A
correctly installed meter should measure equal amounts of  
power consumption in the live and neutral phases. During  
meter tampering the two measurements are no longer equal.  
The SA9607 will use the larger of the two currents for the  
energy measurement. Differences of more than 12% between  
the live and neutral power measurements are indicated on the  
SA9607’s ELT output which can drive a LED directly.  
THE SA9607P MONOCHIP METER WITH ON CHIP  
CALIBRATION  
The SA9607P uses an external EEPROM to store calibration  
data as well as meter specific settings. A major advantage of  
the SA9607P is that no external trim-pots or resistor ladders  
are required to calibrate the meter. This greatly enhances the  
meter reliability and can improve meter production times if  
used in an automatic meter calibration system.  
The SA9607 are designed to drive mechanical counters  
directly. The module is fitted with an impulse type counter that  
increments with a single 71ms pulse. The SA9607 can also  
drive low cost mechanical counters (stepper motors) that use  
two consecutive pulses with opposing voltages to advance the  
counter one position. The SA9607 outputs these two opposing  
pulses in close succession, minimizing the chance of the  
The SA9607P integrated circuit together with an external  
EEPROM provides more meter setup features than the  
SA9607M. Additional information regarding the meter (serial  
numbers, client, and manufacture date) can also be stored in  
the unused sections of the EEPROM memory. An IIC bus  
based EEPROM is used to store configuration and meter  
setup data for the SA9607P. The SA9607P will load this data  
from the EEPROM during power up. During normal meter  
operation it reloads periodically the data from the EEPROM.  
The SA9607P never writes to the EEPROM. For more specific  
configuration information please refer to the SA9607P  
datasheet.  
stepper motor being in the wrong phase after a power failure.  
Calibration pulses, reverse power, earth loop tamper and  
active channel are displayed with four LEDs fitted on the  
module.  
THE SA9607M PIN PROGRAMMABLE MONOCHIP  
METER  
Using the SA9607M, the rated conditions of the meter as well  
as the LED pulse rate and counter resolution can be selected  
for a particular meter design. The meter manufacture is thus  
able to produce a range of meters utilizing the same counter  
and the same metering constant with a single integrated  
circuit. Calibration of the meter is done with trim-pots or  
resistor ladders. Table 1 gives a short list of all the possible  
1/16  
SPEC-0045 (REV. 1)  
19-06-00  

与PM9607AP相关器件

型号 品牌 获取价格 描述 数据表
PM961 ARTESYN

获取价格

Single and dual output 5 to 6 Watt Nominal input DC/DC converters
PM961A ETC

获取价格

Analog IC
PM961B ETC

获取价格

Analog IC
PM962 ARTESYN

获取价格

Single and dual output 5 to 6 Watt Nominal input DC/DC converters
PM962A ETC

获取价格

Analog IC
PM962B ETC

获取价格

Analog IC
PM971 ARTESYN

获取价格

Single and dual output 5 to 6 Watt Nominal input DC/DC converters
PM971A ETC

获取价格

Analog IC
PM971B ETC

获取价格

Analog IC
PM972 ARTESYN

获取价格

Single and dual output 5 to 6 Watt Nominal input DC/DC converters