LinkCom Manufacturing Co., Ltd
Model NO.
Part NO.
LCCE-040ꢀ342
Model Name
Power Supply
PLCCE0040ꢀ342
SIZE
163 * 47 * 31.6 mm 【6.42 * 1.85 * 1.24 inch】
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OTP / OVP
◆ High Operating ambient Temp: -20℃ ~ +60℃
◆ Power Factor: >0.95@115VAC >0.9@230VAC
◆ Safety: UL
◆ EMC: CE / FCC
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension(L*W*H): 163 * 47 * 31.6 mm
◆ Dimension(L*W*H): 6.42 * 1.85 * 1.24 inch
◆ ROHS Compliant
Module : LCCE-040ꢀ342
*,# =SEE NOTES BELOW
LCCE-040ꢀ342
MODEL
*(8)
min.
norm.
12
max.
SPECIFICATION
DC OUTPUT VOLTAGE (V)
PRESET ACCURACY (%) *(7)
OUTPUT CURRENT(A) *(5)
O/P NOISE (P-P, V) *(3)
LINE REGULATION (%) *(6)
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
TURN ON DELAY TIME
INPUT VOLTAGE RANGE
INPUT FREQUENCY
INRUSH CURRENT (typ)
AC CURRENT
5
*
*
*
*
3.4
2.5
10
40.8 W
83%
3000ms at full load 115VAC/230VAC
90-305VAC, 127-431VDC, Normal:100-277VAC
Range:47-63Hz, Normal:50-60Hz
COLD START 43A @ 230VAC
0.7A/100VAC
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
OVER TEMP. PROTECTION
OVER V, PROTECTION
OPERATING TEMP.*(4)
STORAGE TEMPERATURE
RELATIVE HUMIDITY
TEMP. COEFFICIENT
SAFETY
0.75mA/264VAC
The SCP, OTP and OVP will restart automaticalty after the fault condition is removed.
-20 to +60℃@full load
-40 to +80℃
*
10 to +90%
0.03% / ℃ (0-50℃, typ)
UL 60950-1
EMI
CE EN55015 / FCC Part15
163 * 47 * 31.6 mm 【6.42 * 1.85 * 1.24 inch】
DIMENSIONS(L*W*H)
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Line regulation measured from 100VAC to 277VAC.
(7)Preset accuracy measured at normal load, 120VAC input.
(8)100% Production Tested.
www.linkcom.com.tw For more information, please contact with: sales@linkcom.com.tw
※Reference