FUSES / SICHERUNGEN
PFRT
Resettable fuses / Rückstellende Sicherungen
Telecom / Telecom
Typical Time to Trip at 23 ˚C
Wire leaded
PTC-Fuses
Type PFRT
High voltage surge
capabilities
Compliance to ITU
K.20/K.21 specifications
Agency recognition:
UL, CSA, TÜV
100
100
10
PFRT.018.250.U
1
0.10
0.01
PFRT.014.250 & PFRT.014.250.U
PFRT.012.250 & PFRT.012.250.U
PFRT.011.250.U
PFRT.008.250 & PFRT.008.250.U
0
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3
50
75
100
Fault current (A)
Typical Part Marking
Dimensions
A
Layout may vary
E
Manufacturer’s Trademark
Restance bin
Part identification
B
Date code (First digit = Last digit of
year; next three digits = day of year)
Lot No. (T = Taiwan, S = Xiamen)
C
D
Applications
Used as a secondary overcur-
rent protection device in:
•
Customer Premise Equipment
(CPE)
•
•
Central Office (CO)
Subscriber Line Interface
Cards (SLIC)
Environmental Characteristics
Operating/Storage Temperature / Einsatz/Lagertemp.
Maximum Device Surface Temperature in Tripped State / 125 °C
-45 °C to +85 °C
Passive Aging / passive Alterung
+85 °C, 1000 hours / Std.
+60 °C, 1000 hours / Std.
± 2% typ. resist. change
± 3% typ. resist. change
Humidity Aging / Feuchtigkeitsalterung
Thermal Shock / Thermischer Schock
+85 °C, 85% R.H. 500 hours / Std. ± 3% typ. resist. change
MIL-STD-202F, Method 107G ±10% typ. resist. change
+125 °C/–55 °C, 10 times / Zyklen ±15% typ. resist. change
Solvent Resistance / Lösungsmittel-Beständigkeit
Lead Solerability / Lötbarkeit
Flammability / Entflammbarkeit
Vibration
MIL-STD-202, Method 215B
ANSI/J-STD-002
IEC 695-2-2
MIL-STD-883C, Method 2007.1,
Condition A
No change
No Flame for 60 sec.
No change
Test Procedures And Requirements For Model PFRT Series
Test / Test
Test Conditions / Bedingungen
Accept/Reject Criteria
Visual/Mech. / visuell/mech.
Resistance / Widerstand
Time to Trip / Trip-Zeit
Hold Current / Haltestrom
Trip Cycle Life / Trip-Zyklen
Verify dimensions and materials / Kontrolle Abmess./Mat. Per MF physical description
In still air @ 23 °C / bei ruhiger Luft 23 °C
5 times Ihold, Vmax 23 °C / 5-facher Haltestrom
30 min. at Ihold / bei Haltestrom
Rmin ≤ R ≤ Rmax
T ≤ max. time to trip (sec.)
No trip
Vmax, Imax, 100 cycles / Zyklen
No arcing or burning
No arcing or burning
Trip Endurance / Zeit im Tripzustand Vmax, 48 hours / Stunden
121