ISOLATED OUTPUT HIGH PRECISION CURRENT SHUNT METER

PCS-1000I 数据手册

 浏览型号PCS-1000I的Datasheet PDF文件第2页 
ISOLATED OUTPUT HIGH PRECISION CURRENT SHUNT METER  
PCS-1000I  
FEATURES  
6 1/2 Digit Voltage and Current  
Measurement Resolution  
Simultaneous Current and Voltage  
Measurement  
Five Current Measurement Levels(AC  
& DC) : 30mA/300mA/3A/30A/300A  
AC Voltage Measurement Levels :  
200mV/2V/20V/200V/600V  
DC Voltage Measurement Levels :  
200mV/2V/20V/200V/1000V  
Standard : USB & GPIB  
GW Instek rolls out the new PCS-1000I isolated output  
high precision current shunt meter, which inherits the  
Connection Comparison  
PCS-1000I can simultaneously measure current and  
voltage with 6 1/2 measurement resolution. The  
below diagram shows the connection method of  
simultaneous voltage and current measurement function  
of PCS-1000. PCS-1000I adopts five sets of independent  
shunt resistors to provide five current measurement  
simultaneous measurement. Compared with the test  
levels, including 300A, 30A, 3A, 300mA, and 30mA to  
of conventional meters from other brands, PCS-1000I  
meet the requirements of different current level  
is simple in connection and there is no requirement  
measurements. Internally, PCS-1000I utilizes two sets  
of 24bits ADCs and low temperature coefficient  
CE Verification  
of any additional instrument.  
electronic components to mainly focus on the current  
PCS-1000I Conducts Simultaneous Voltage  
measurement of power supply devices. High precision  
and Current Measurement  
PCS-1000I can be used in adjusting and calibrating  
instruments. Additionally, temperature variation will not  
cause PCS-1000I to yield any measurement errors. PCS-  
1000I can automatically select optimal measurement  
level with the maximum resolution so as to replace  
manual selection to save operational time.  
PCS-1000I provides a BNC output, which can connect  
with an oscilloscope to directly observe current  
waveform variation without using a current probe.  
General oscilloscopes do not have isolated channels  
and their input and output are structured at a common  
point, therefore, the output load will likely result in  
and current  
1.Only one PCS-1000I is needed to measure voltage  
Front Panel  
measurement errors. PCS-1000I's isolated current  
2.Easy connection  
output design can prevent measurement errors from an  
3.USB and GPIB communications on the rear panel  
oscilloscope with non-isolated outputs. PCS-1000I, a  
can be used for data communication while  
high precision AC/DC current shunt meter, not only  
connecting with a PC  
provides USB and GPIB communications interfaces for  
users to remotely control the instrument but also  
conducts simultaneous voltage and current  
measurements. The SCPI communications commands  
of PCS-1000I allow users to remotely control PCS-1000I  
via a PC to operate measurement data readbacks.  
Shunt Resistor Conducts Current and Voltage  
Measurement  
Rear Panel  
1.One voltage meter is needed to measure voltage on  
shunt and the voltage will be converted to current.  
For simultaneous voltage and current measurement,  
one extra voltage meter is required  
PCS-1000I high precision AC and DC shunt meter can  
2.Complex connection  
simultaneously measure current and voltage with the  
3.For data communication with a PC, the PC must be  
maximum 6 1/2 measurement resolution. The above diagram  
connected to two voltage meters  
PCS-1000I  
shows the connection method of simultaneous measurement.  
Compared with the test of conventional meters from  
vs. Current Probe for Measurement  
Conventional Shunt Meter Conducts Current  
and Voltage Measurement  
other brands, PCS-1000I is simple in connection and  
there is no requirement of any additional instrument.  
Isolated Output Current  
Output Design  
APPLICATIONS  
Power Supply Analysis  
Power Supply Measurement Application  
R & D and Laboratory Application  
Quality Inspection Test  
1.This method requires one shunt meter, one current  
meter to increase current measurement resolution,  
and one voltage meter to measure voltage  
2.Complex connection  
Precision Measurement  
PCS-1000I adopts isolated current output design. Its  
BNC output can directly connect with an oscilloscope  
to avoid measurement errors resulted from the common  
ground of oscilloscope's analog input measurement.  
3.For data communication with a PC, the PC must be  
connected to two meters  
Simply Reliable  
PCS-1000I  

与PCS-1000I相关器件

型号 品牌 获取价格 描述 数据表
PCS1014-100T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-150T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-220T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-2R2T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-2R7T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-330T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-3R3T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-4R7T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS1014-6R8T-RC ALLIED

获取价格

Power Chip Shielded Inductors
PCS103 ALLIED

获取价格

Power Chip Shielded Inductors