PC817 Series
High Density Mounting Type
Photocoupler
PC817 Series
(
)
(
)
(
)
❈ Lead forming type I type and taping reel type P type are also available. PC817I/PC817P
..
(
)
❈❈ TUV VDE0884 approved type is also available as an option.
■ Features
■ Applications
1. Current transfer ratio
1. Computer terminals
(
,VCE=5V)
CTR: MIN. 50% at I F = 5mA
2. System appliances, measuring instruments
3. Registers, copiers, automatic vending
machines
2. High isolation voltage between input and
( )
Viso : 5 000V rms
output
3. Compact dual-in-line package
PC817 : 1-channel type
4. Electric home appliances, such as fan
heaters, etc.
PC827 : 2-channel type
5. Signal transmission between circuits of
different potentials and impedances
PC837 : 3-channel type
PC847 : 4-channel type
4. Recognized by UL, file No. E64380
(
)
■ Outline Dimensions
Unit : mm
PC817
PC827
Internal connection diagram
Internal connection diagram
2.54± 0.25
2.54± 0.25
8
7
6
5
4
3
8
7
6
5
4
3
CTR
rank mark
Anode
mark
Anode mark
1
2
1
2
3
4
1
3
4
2
1 3 Anode
1
2
± 0.2
0.9
0.9± 0.2
2 4 Cathode
5 7 Emitter
6 8 Collector
± 0.3
1.2
1.2± 0.3
7.62± 0.3
7.62± 0.3
4.58± 0.5
9.66± 0.5
1
2
3
4
Anode
Cathode
Emitter
Collector
0.26± 0.1
0.26± 0.1
θ
θ
θ
θ
θ= 0 to 13˚
0.5± 0.1
0.5± 0.1
θ = 0 to 13 ˚
PC837
PC847
Internal connection
diagram
Internal connection
diagram
2.54± 0.25
2.54± 0.25
10
10
9
8
7
6
10
12 11
9
8
14 13 12 11
16
15
9
8
7
6
16 15 14 13 12 11 10
9
12
11
1
2
3
4
5
1
2
3
4
5
6
8
7
1
2
3
4
5
6
7
1 3 5 Anode
2 4 6 Cathode
7 9 11 Emitter
8 10 12 Collector
1
2
3
4
5
0.9± 0.2
1.2± 0.3
0.9± 0.2
1.2± 0.3
7.62± 0.3
19.82± 0.5
7.62± 0.3
14.74± 0.5
0.26± 0.1
θ
θ
0.26± 0.1
0.5± 0.1
θ = 0 to 13˚
θ
θ
13 15
9 11
10
Emitter
12 14 16 Collector
0.5± 0.1
1 3 5 7 Anode
2 4 6 8 Cathode
θ = 0 to 13˚
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”