Relay
vy Duty Power
Two Pole Hea
PC738
FEATURES
vy duty switching
Two poles of hea
tching capacity
wer rating
Up to 30 amp swi
Up to 2.5 horsepo
Meets 8mm creep
4KV dielectric
age distance
tion standard
led version available
als
UL Class F insula
Dust cover or sea
QC or PCB termin
File # E93379
UL/CUR RATINGS
2 Form C (DPDT)
2 Form A
Load Type
Voltage
NO
(DPST-NO)
NC
120 VAC
277 VAC
28 VDC
30 A
30 A
20 A
30 A
30 A
20 A
3 A
3 A
3 A
General Purpose
120 VAC
240 VAC
30 A
30 A
30 A
30 A
3 A
3 A
Resistive
Motor
250 VAC
120 VAC
2.5 HP
1 HP
2.5 HP
1 HP
LRA/FLA
(locked rotor amps/full load
240 VAC
120 VAC
110 A/25.3 A
110 A/25.3 A
110 A/25.3 A
110 A/25.3 A
amps)
240 VAC
120 VAC
TV 10
TV 10
TV 10
TV 10
Tungsten
CONTACT DATA
xide)
AgCdO (Silver Cadmium O
50 milliohms max @ 1A, 6V
5 X 106 Operations
Material
DC
Initial Contact Resistance
Mechanical
Electrical
Service Life
1 X 105 Operations
S
CHARACTERISTIC
Operate Time
15 ms. typical
10 ms. typical
Release Time
0VDC, 50%RH
1,000 megohms min, at 50
Insulation Resistance
coil and contacts
open contacts
contact poles
4000 Vrms, 1 min. between
1500 Vrms, 1 min. between
2000 Vrms, 1 min. between
Dielectric Strength
g, destructive
Shock Resistance
Vibration Resistance
Power Consumption
10 g, 11ms, functional; 100
DA 1.65mm, 10-55 Hz
DC coil 1.7W, AC coil 4 VA
130 C storage
nge
Ambient Temperature Ra
Weight
DC co
il: -55 to 85 C, AC coil: -55 to 65 C operating, -40 to
86 grams approx.
PC738 Rev B 3-25-04
06
uite 102, Carrollton, Texas 750
3220 Commander Drive, S
997-3933 Fax (818) 342-5296
Sales: Call Toll Free (888)
om
.net URL: pickercomponents.c
email: pickerwest@sbcglobal
PAGE 1