Ordering information
AC-DC Power Supplies Enclosed type
PB
W
15
F
-O -O
5 6
PBW15F
1
2
3
4
1Series name
2Dual output
3Output wattage
4Universal input
5Output voltage
6Optional *10
C :with Coating
Recommended EMI/EMC Filter
NAC-06-472
PBA/PBW
R
G :Low leakage current
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
E :Low leakage current
and EMI class A
*The EMI/EMC Filter is recommended
*to connect with several devices.
T :Vertical terminal block
J :Connector type
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
PBW15F-12
16.8
PBW15F-15
15.0
5
*
6
*
(
)
(
)
VOLTAGE[V]
12 +24
15 +30
t
t
DC OUTPUT
CURRENT1[A] 0.7
0.5
5
*
CURRENT2[A]
1.4
1.0
SPECIFICATIONS
MODEL
PBW15F-12
PBW15F-15
(
)
8
*
VOLTAGE[V]
AC85 - 264 1 or DC110 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
f
(
(
)
)
ACIN 100V 0.40typ CURRENT1
CURRENT[A]
ACIN 200V 0.20typ CURRENT1
( )
50/60 47 - 440 or DC
FREQUENCY[Hz]
(
(
)
)
(
78typ CURRENT1
(
80typ CURRENT1
)
)
INPUT
ACIN 100V 74typ CURRENT1
EFFICIENCY[%]
ACIN 200V 77typ CURRENT1
(
(
) (
) (
)
)
ACIN 100V 15typ CURRENT1 At cold start
INRUSH CURRENT[A]
ACIN 200V 30typ CURRENT1 At cold start
(
,
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.15/0.30max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN
(
)
(
)
+30V reference number
12
t
/
+24V reference number
15
t
/
CURRENT1[A]
0.7
/ 0.7
0.5
/ 0.5
5
9
CURRENT2[A]
*
*
1.4
/ -
1.0
/ -
LINE REGULATION[mV]
LOAD REGULATION 1[mV]
LOAD REGULATION 2[mV]
60max
600max
750max
120max
160max
150max
180max
120max
150max
48max
/ 96max
/ 150max
/ -
/ 240max
/ 320max
/ 300max
/ 360max
60max
600max
750max
120max
160max
150max
180max
150max
180max
60max
/ 96max
/ 150max
/ -
/ 240max
/ 320max
/ 300max
/ 360max
11
*
*
*
3
*
11
4
*
11
1
0 to +50
*
C
RIPPLE[mVp-p]
1
*
1
*
1
*
-10 - 0
C
OUTPUT
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
-10 to +50
C
TEMPERATURE REGULATION[mV]
C
2
*
DRIFT[mV]
(
(
,
)
200typ ACIN 100V Io=100%
*
START-UP TIME[ms]
HOLD-UP TIME[ms]
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
,
)
20typ ACIN 100V Io=100%
(
)
(
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 9.60 - 13.2 +V and -V are simultaneously adjusted
13.2 - 16.5 +V and -V are simultaneously adjusted
(
)
(
)
OUTPUT VOLTAGE SETTING[V] 11.5 - 12.5 +V and -V CURRENT1
14.4 - 15.6 +V and -V CURRENT1
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V] 16.8 - 24.0
PROTECTION
CIRCUIT AND
OTHERS
20.0 - 29.0
(
)
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
LED Green
None
,
,
,
(
)
)
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
W
ISOLATION
,
,
(
)
OUTPUT-FG
AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
,
(
),
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
,
(
)
,
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
VIBRATION
IMPACT
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
(
)
,
(
),
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
NOISE
, , , ,
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
Complies with IEC61000-3-2 Not built-in to active filter
31 78 85mm [1.22 3.07 3.35 inches] without terminal block
Convection
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
REGULATIONS
(
)
12
*
7
*
(
) ( )
W H D
X X
(
)
/
200g max without cover
X
X
X
X
OTHERS
side is fixed.
*1 Measured by 20MHz oscilloscope or Ripple-Noise
*10Please contact us about safety approvals for the model with
option.
*11Please contact us about dynamic load and input response.
*12Please contact us about class C.
*5 The sum of +power -power must be less than output power.
*6 t12,t15 can be used as +24 and +30.
*7 When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.
*8 Derating is required.
meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3 Figures for 0 to rated current 1.The current not measured
side is fixed.
*4 Figures for 0 to rated current 2.The current not measured
*
*
*
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.
*9 Figures to rated current 1.
PBA/PBW-26