Ordering information
Unit type
PBA
PBA 600
F
-5
-O
5
PBA600F
1
2
3
4
1Series name
R
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1
MODEL
PBA600F-3R3 PBA600F-5
PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
MAX OUTPUT WATTAGE[W]
396
600
600
636
645
648
648
624
ACIN 100V 3.3V 120A
5V 120A
5V 120A
7.5V 80A
7.5V 80A
12V 53A
12V 53A
15V 43A
15V 43A
24V 27A
( )
24V 27 31 A
36V 18A
36V 18A
48V 13A
48V 13A
DC OUTPUT
3
*
ACIN 200V
3.3V 120A
SPECIFICATIONS
MODEL
PBA600F-3R3 PBA600F-5
AC85 - 264 1 or DC120 - 350
PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
VOLTAGE[V]
f
ACIN 100V 5.8typ
8.2typ
4.1typ
CURRENT[A]
ACIN 200V 3typ
( )
50/60 47 - 63
FREQUENCY[Hz]
ACIN 100V 70typ
ACIN 200V 72typ
75typ
77typ
76typ
79typ
79typ
82typ
79typ
82typ
81typ
84typ
82typ
84typ
81typ
83typ
EFFICIENCY[%]
INPUT
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.95typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More than 3 sec. to re-start
INRUSH CURRENT[A]
ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 3 sec. to re-start
(
,
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45/0.75max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1
3.3
5
7.5
12
15
24
27
27 31
36
18
18
48
13
13
ACIN 100V 120
120
120
80
80
53
53
43
43
CURRENT[A]
3
*
(
)
ACIN 200V
120
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
80max
140max
120max
160max
40max
60max
12max
20max
40max
80max
140max
120max
160max
50max
75max
20max
36max
60max
120max
160max
150max
180max
75max
120max
30max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
150max
120max
160max
150max
180max
240max
290max
96max
1
*
1
*
1
*
1
*
1
*
1
*
2
*
0 to +50
C
RIPPLE[mVp-p]
-20 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
-20 - 0
C
0 to +50
C
-20 to +50
C
DRIFT[mV]
( , )
400typ ACIN 100/200V Io=100% Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
START-UP TIME[ms]
HOLD-UP TIME[ms]
(
,
)
20typ ACIN 100/200V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
3.96 - 6.00
5.00 - 5.15
5.25 - 8.25
7.50 - 7.80
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
4
*
OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
PROTECTION
(
)
LED Green
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Provided
Provided
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
ISOLATION
,
,
(
)
OUTPUT RC AUX-FG
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
-
-
W
,
,
(
)
OUTPUT-RC AUX
AC100V 1minute Cutoff current = 100mA DC100V 50M min At Room Temperature
-
W
,
,
,
( ) , ( , )
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +71
20 - 90%RH Non condensing 3 000m 10 000feet max
C
,
(
)
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 3 000m 10 000feet max
),
C
ENVIRONMENT
19.6m/s2 2G 10 - 55Hz 3minutes period 60minutes each along X Y and Z axis
(
,
,
,
VIBRATION
196.1m/s2 20G 11ms once each X Y and Z axis
(
),
,
,
IMPACT
,
(
),
,
(
)
AGENCY APPROVALS
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN At only AC input
SAFETY AND
NOISE
,
,
,
,
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
Low Voltage Directive EMC Directive
Complies with IEC61000-3-2
120 61 190mm without terminal block and screw
,
REGULATIONS
(
) (
W
)
H D /1.6kg max
X
X
X
X
OTHERS
(
)
Forced cooling internal fan
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
*4 Overvoltage protection circuit to follow to output voltage setting.
*
A sound may occur from power supply at pulse loading.
A-14