Footswitches
PX/ PA
Heavy duty footswitches with shrouded pedal to prevent
accidental operation
■
Large shroud to allow operators to wear industrial protective
footwear
■
Pedal interlock lever to prevent operation unless the
operator’s foot is fully inside the pedal shroud
10A 500VAC/ 600VDC rated
Bifurcated contacts for low resistance and high reliability –
suitable for switching low-level electronic currents
Positive break of NC contacts for safety circuits in
conformity with BS60947-5-1, VDE 0660 part 206 and IEC
337-1
A second contact block can be fitted giving a total of four
contacts in various combinations of NO and NC
Unshrouded models (stop type) with red terminal cover
Impact-resistant glass-reinforced thermoplastic housing
Non-skid rubber feet plus floor-fixing holes if required
Double insulated for electrical safety
■
■
■
■
■
■
■
■
■
■
■
Mechanism protected against dirt and foreign matter
Cable entry hole with PG13.5 thread
IP65
Options and ordering codes
PRICE
Footswitches:
Additional contact blocks if required:
INFORMATION
AND ORDERING
PX 10111
PX 10311
PX 10121
PA 20101
PA 20321
PA 20701
Shrouded, snap-action 1NO + 1NC
B501
1NO + 1NC snap-action
Shrouded, slow-action 1NO + 1NC
B601
1NO + 1NC slow-action
Shrouded, latching, snap-action 1NO + 1NC
Unshrouded, snap-action 1NO + 1NC
B901
2NC slow-action
2NO slow-action
Unshrouded, latching, slow-action 1NO + 1NC
Unshrouded, slow-action 2NC
B1001
Many other footswitch models available including double-pedal types - contact IMO for availability
Cable glands
Contact blocks
Cable glands are available to enable standard multi-core cables to be connected
without the use of conduit. Two sizes are possible:
The contact blocks can also be purchased
separately without the footswitches and be
used as stand-alone limit switches.
The contacts are electrically separated so it is
possible to connect different voltages to NO and
NC circuits i.e. Zb contacts. The NC contacts also
have positive break, i.e. suitable for safety circuits.
Contact arrangements:
P ar t number
P G1 3 .5
P G1 3 .5 / 6
Cable size
ø9-12mm
ø6-9mm
See previous page
for diagram
Plug and socket footswitches
1NO+1NC
13 21
All PX series footswitches can be converted to a plug-in style by the addition of
an adaptor. See previous page for diagram.
The adaptor is screwed into the footswitch and the four flying leads connected to
the four terminals of the contact block.
1NO+1NC
13 21
B501
B901
B601
14 22
14 22
Terminal screws: M3.5
with rising cable clamps.
Maximum screw
Suitable 4-wire plug leads are available – see pages 332 to 335
2NO
13 23
2NC
11 21
Ratings
250VAC/ 300VDC
3A
IP67
B1001
tightening torque:
0.8Nm (8kg cm).
Note: There is space under the ter minal cover to allow the fitting of a small amount of
control components, e.g. relays, ter minal blocks etc., which should be secured to
prevent inter ference with the footswitch mechanism.
14 24
12 22
Specifications
Contact ratings
Rated ther mal cur rent Ith
10A
BS/ EN 60947-5-1
Rated working voltage
Initial contact resistance
Contact gap
500VAC/ 600VDC
<25 mOhms
>2.5mm (2 x 1.25mm conforming to VDE 0660 part 206)
silver
AC15
230VAC
400VAC
500VAC
6A
4A
1A
Contact material
2000VAC, 50/ 60Hz for 1 minute between open contacts
2000VAC, 50/ 60Hz for 1 minute between current-carrying parts and ground
Dielectric strength
Ambient operating temperature
Ambient humidity
Maximum wire size
Conduit entr y
–25 to +80 deg. C
95% r.h.
DC13
24VDC
125VDC
250VDC
6A
1.1A
0.4A
2 x 1.5mm2 flexible, 2 x 2.5mm2 solid