P4SMA SERIES
SURFACE MOUNT TRANSIENT VOLTAGE SUPPRESSOR POWER 400 Watts
6.8 to 250 Volts
BREAK DOWN VOLTAGE
FEATURES
• For surface mounted applications in order to optimize board space
• Glass passivated junction
• Low inductance
• Plastic package has Underwriters Laboratory Flammability
Classification 94V-O
0.181(4.60)
0.157(4.00)
• High temperature soldering : 260°C /10 seconds at terminals
• Lead free in comply with EU RoHS 2011/65/EU directives
• Green molding compound as per IEC61249 Std. . (Halogen Free)
0
0
.
.
012(0.305)
006(0.152)
MECHANICAL DATA
• Case: JEDEC DO-214AC,Molded plastic over passivated junction.
• Terminals: Solder plated,solderable per MIL-STD-750, Method 2026
• Polarity: Color band denotes cathode end
0.008(0.203)
0.002(0.051)
0.060(1.52)
0.030(0.76)
0.208(5.28)
0.188(4.80)
• Standard Packaging:12mm tape (EIA-481)
• Weight: 0.002 ounce, 0.064 gram
DEVICES FOR BIPOLAR APPLICATIONS
For Bidirectional use C or CA Suffix for types P4SMA6.8 thru types P4SMA250.
Electrical characteristics apply in both directions.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Rating
Symbol
PPP
Value
400
Units
Peak Pulse Power Dissipation on TA = 25OC (Notes 1,2,5, Fig.1)
Peak Forward Surge Current per Fig.5 (Notes 3)
Watts
IFSM
40
Amps
Amps
OC / W
OC
Peak Pulse Current on 10/1000μs waveform (Notes 1)Fig.2
Typical Thermal Resistance Junction to Air (Notes 2)
Operating Junction and Storage Temperature Range
IPPM
see Table 1
70
RθJA
TJ,TSTG
-55 to +150
NOTES :
1. Non-repetitive current pulse, per Fig.3 and derated above TA = 25OC per Fig. 2.
2. Mounted on 5mm2 copper pads to each terminal.
3. 8.3ms single half sine-wave, or equivalent square wave, duty cycle = 4 pulses per minutes maximum.
4. Lead temperature at 75OC = TL.
5. Peak pulse power waveform is 10/1000μs.
6. A transient suppressor is selected according to the working peak reverse voltage (VRWM), which should be equal to or greater than the DC
or continuous peak operating voltage level.
November 22,2012-REV.06
PAGE . 1