MODEL: OT2
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)
Plug-in Signal Conditioners M-UNIT
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
OPTICAL TRANSMITTER
Functions & Features
• Isolation up to several hundred thousand volts with a fiber
optics cable
• High-density mounting
[2] POWER INPUT
AC Power
Typical Applications
• Ion implanter
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
G: 200 V AC
H: 220 V AC
J: 240 V AC
• Electron-beam devices
• Dust chamber
• Protection against inductive noises in power substations
50
(1.97)
DC Power
M·UN
IT
Mo
d
80
(3.15)
e
OTl
S: 12 V DC
M·
M
U
e
N
2
L
TE
IT
o
d
l
O
N
P
T
M
IC
IT
A
OR
IC
T
RA
2
L
R
S
R
O
E
P
C
T
A
E
R
E
IV
R: 24 V DC
123
(4.84)
[3] OPTIONS
blank: none
mm (inch)
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
MODEL: OT2-[1]-[2][3]
/C02: Polyurethane coating
ORDERING INFORMATION
• Code number: OT2-[1]-[2][3]
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
Specify a code from below for each of [1] through [3].
(e.g. OT2-6-B/Q)
• Special input range (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
RELATED PRODUCTS
• Optical receiver (Model: OR2)
• Fiber optics cable:
10 meters (model: AMPCP2-10M)
20 meters (model: AMPCP2-20M)
30 meters (model: AMPCP2-30M)
Optical cable used for the AMPCP2
Mitsubishi Chemical Super Eska SH 4001
Minimum bend radius: 25 mm
Tension strength: ≤ 70 N
[1] INPUT
Current
A: 4 – 20 mA DC (Input resistance 250 Ω)
A1: 4 – 20 mA DC (Input resistance 50 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
Connector used for the AMPCP2
Broadcom HFBR-4532Z
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)
OT2 SPECIFICATIONS
ES-3204 Rev.2 Page 1/4
http://www.m-system.co.jp/