OPA4277-SP
SBOS771A –DECEMBER 2016–REVISED JANUARY 2019
OPA4277-SP Radiation Hardened High-Precision Operational Amplifier
The OPA4277-SP operates from ±2- to ±18-V
supplies with excellent performance. Unlike most
operational amplifiers which are specified at only one
1 Features
1
•
QMLV Qualified: 5962-16209
–
Radiation Hardness Assurance (RHA) up to
Total Ionizing Dose (TID) 50 krad(Si)
supply
voltage,
the
OPA4277-SP
precision
operational amplifier is specified for real-world
applications; a single limit applies over the ±5- to ±15-
V supply range. High performance is maintained as
the amplifier swings to the specified limits.
–
–
ELDRS-Free (See Radiation Report)
Single Event Latchup (SEL) Immune to LET =
85 MeV-cm2/mg
The OPA4277-SP is easy to use and free from phase
inversion and overload problems found in some
operational amplifiers. It is stable in unity gain and
provides excellent dynamic behavior over a wide
range of load conditions. The OPA4277-SP features
completely independent circuitry for lowest crosstalk
and freedom from interaction, even when overdriven
or overloaded.
•
•
•
•
•
•
•
•
Ultra-Low Offset Voltage: 20 µV
Ultra-Low Drift: ±0.15 µV/°C
High Open-Loop Gain: 134 dB
High Common-Mode Rejection: 140 dB
High-Power Supply Rejection: 130 dB
Wide Supply Range: ±2 to ±18 V
Low-Quiescent Current: 800 µA/Amplifier
Device Information(1)
Available in 14-lead CFP With Industry Standard
Quad Operational Amplifier Pinout
PART NUMBER
5962L1620901VYC
5962L1620901VXA
5962L1620901V9A
GRADE
PACKAGE
14-lead CFP (HFR)
28-lead CDIP (JDJ)
KGD(2)
50 krad(Si)
ELDRS-free
2 Applications
•
•
•
Space Satellite Temperature and Position Sensing
High-Accuracy Space Instrumentation
Engineering
Samples(3)
OPA4277HFR/EM
14-lead CFP (HFR)
Space Precision and Scientific Applications
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
–
–
–
–
Transducer Amplifier
Bridge Amplifier
(2) KGD = known good die.
(3) These units are intended for engineering evaluation only.
They are processed to a noncompliant flow. These units are
not suitable for qualification, production, radiation testing or
flight use. Parts are not warrantied for performance over the
full MIL specified temperature range of –55°C to 125°C or
operating life.
Strain Gage Amplifier
Precision Integrator
3 Description
The OPA4277-SP precision operational amplifier
replaces the industry standard LM124-SP. It offers
improved noise and two orders of magnitude lower
input offset voltage. Features include ultra-low offset
voltage and drift, low-bias current, high common-
mode rejection, and high-power supply rejection.
Simplified Schematic
R2
R1
OPA4277-SP
No bias current
cancellation resistor
Copyright © 2016, Texas Instruments Incorporated