Total Power:
Input Voltage:
200-350 Watts
85-264 VAC
120-300 VDC
Single
350 Watts
# of Outputs:
NTS350 Series
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
85-264 VAC; 120-300 VDC
47-440 Hz
38 A max., cold start @ 25°C
85% typical at full load
EMI filter
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and
radiated.
Power factor
0.99 typical
Safety ground
leakage current
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Special Features
Maximum power
200W convection; 350 W with 30 CFM
forced air
5%
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 5V standby
• 12V fan output
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Built in OR-ing diode / FET
• Optional fan cover (-CF suffix)
Adjustment range
Standby output
Fan output
5 V @ 2A regulated, 5%
12 V @ 1A, -5 %, +7%, 0.5A for -CF version
20 ms @ 350 W load, 115 VAC nominal
line at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 115-130%
above peak rating
Hold-up time
Overload protection
Overvoltage protection
20% to 35% above nominal output
Logic Control
Power failure
TTL logic signal goes high 100-500 msec
after main output. It goes low at least 4
msec before loss of regulation
Requires an external contact closure to
inhibit outputs
TTL logic goes high after the output is in
regulation. It goes low when there is loss
of regulation.
Remote on/off
DC OK
Environmental
Remote sense
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection protected.
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -4, -5, -11 Level 3
Humidity: Operating; non-condensing
10% to 90%
Safety
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
2 G peak 8 Hz to 500 Hz, operational
TUV
UL
CSA
NEMKO
AUSTEL
CB
60950
60950
60950
60950
60950
Storage temperature: -40° to 85°C
Temperature coefficient: .04% per °C
MTBF demonstrated: >1M hours at full load and
25°C ambient conditions
Certificate and report
Mark (LVD)
CE
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
1