Total Power: 70-120 Watts
Input Voltage: 36-72 VDC
# of Outputs: Quad
70-125 Watts
NTQ123-DC Series
Electrical Specs
Input
Input range
Inrush current
Efficiency
36-72 VDC
38 A max., cold start @ 25°C
65% typical at full load
FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B conducted
and radiated, VDE 0878 PT3 Class B
conducted and radiated.
EMI filter
Safety ground
Leakage current
<1 mA @ 72 VDC input
Output
Maximum power
70 W convection,
125 W with 30 CFM forced air
±5% minimum on outputs one and two
20 ms @ 120 W load, -48 VDC input
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
Special Features
Adjustment range
Hold-up time
• -48 VDC input
Overload protection
• Remote sense on outputs one and two
• Power fail and remote inhibit
• Single wire current sharing on outputs one
and two
Overvoltage protection
3.3 V and 5 V output: 10% to 35%
above nominal output
• Adjustable main outputs
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
Logic Control
Power failure
TTL logic signal goes high 100-500
msec after 5 V output; it goes low at
least 4 msec before loss of regulation
Requires an external TTL Signal to
inhibit outputs
Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protection.
• Thermal overload protection
Remote Inhibit
Remote sense
Environmental
Operating temperature: 0° to 50°C ambient; derate
each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Safety
Storage temperature: -40° to 85°C
VDE
0805/EN60950 (IEC950)
Temperature coefficient: ± .04% per °C
UL
UL1950
MTBF demonstrated: >1 million hours at full load
and 25°C ambient conditions
CSA
NEMKO
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
CB
CE
Certificate and report
Mark (LVD)
108
America’s (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
rev 02.17.03