NTE805
Integrated Circuit
IF Gain Block for FM Receiver
Description:
The NTE805 provides function of an IF gain block and is designed for use in communications and FM
receivers. The device consists of a three−stage limiting amplifier operating from a regulated power
supply, and 330Ω input and output terminations with 7.0pF of shunt capacitance required for 10.7MHz
ceramic filters. The device also offers a 7.7 voltage regulated supply for external use from pin 6.
Features:
D Gain at 10.7MHz: 35dB Typ.
D Operating Voltage Range: 10V to 20V
D Excellent Temperature Stability
D Power Supply Rejection Ratio: 40dB Typ.
Absolute Maximum Ratings:
Supply Voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20V
Supply Current, ICC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30mA
Input Voltage (Pin 1 and Pin 3), VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3.0V
Internal Power Consumption (PD at 70°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400mW
Output Current (Pin 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mA
Operating Temperature Range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −25° to +70°C
Storage Temperature Range, TS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65° to +150°C
Note 1. Derate at the rate of 8.3mW°C at temperatures above +25°C
Operating Conditions: (TA = +25°C, VCC = 12V unless otherwise specified)
Parameter
Supply Current
Symbol Test Pin
Test Conditions
Min Typ Max Unit
ICC
Pd
V1
V2
V3
V5
V6
V7
8
14
−
18
−
25
mA
Total Device Dissipation
Terminal Voltage (Note 2)
400 mW
1
1
1
1
1
1
−
1.2
1.2
2.4
2.0
7.7
2.0
−
−
V
V
V
V
V
V
−
−
−
−
−
I6 = 5mA
7.2
−
8.3
−
Note 2. All DC Voltage readings are with respect to network ground.