5秒后页面跳转
NTE8000 PDF预览

NTE8000

更新时间: 2022-04-20 13:34:41
品牌 Logo 应用领域
NTE /
页数 文件大小 规格书
1页 58K
描述
Radial Lead Thermal Cutoff

NTE8000 数据手册

  
NTE8000 thru NTE8035  
Radial Lead Thermal Cutoff  
(Thermal Fuse)  
Description:  
The TCO (Thermal Cut-Off) responds to temperature by interrupting an electrical circuit when the operating and/or environ‐  
mental temperature exceeds the thermal rating of the device. NTE's radial lead TCOs accomplish this when the internal  
fusible alloy is melted by reaching the temperature of the melting point of the alloy, forming two separate balls at the edges  
of the leads by surface tension of the alloy to permanently open the circuit.  
Axial-lead TCO devices presently predominate over radial-lead devices. This results, at least in part, from design diffi‐  
culties that exist in manufacturing a reliable, inexpensive radial-lead TCO device. However, in many circuit applications  
radial-lead devices are preferable since they take up a smaller area on a printed circuit board. Their compact size enables  
ease of assembly into the smallest of transformers ensuring total thermal protection  
Features  
D
D
D
D
Maximum Rating: 5 Amps, 250 Volts  
Full 2 3/4” leads to fit all replacement configurations  
All types meet the requirements of Underwriters Laboratories Specifications and CUL  
RoHS Compliant  
Characteristics  
Functioning  
Holding  
Maximum  
Temperature Temperature Temperature  
Diagram 729  
.106 (2.7)  
.260 (6.6)  
NTE  
Type No.  
Diag.  
No.  
°C  
76  
°F  
°C  
53  
°F  
°C  
°F  
8000  
8005  
8010  
8015  
8020  
8025  
8030  
8035  
729  
729  
729  
729  
729  
729  
729  
729  
168  
187  
216  
239  
266  
277  
293  
302  
127  
142  
171  
192  
217  
232  
244  
253  
200  
200  
200  
200  
200  
200  
200  
200  
392  
392  
392  
392  
392  
392  
392  
392  
.276  
(7.0)  
86  
61  
102  
115  
130  
136  
145  
150  
77  
89  
2.756  
(70.0)  
103  
111  
118  
123  
.031 (0.8)  
Note 1. Temperature sensitive devices. Do not store above +48°C (+120°F).  
Note 2. With proper air flow, heat generation below 5 Amps is minimal, above 5 Amps the upper limit on the currentcapac‐  
ity will depend on the environment for each specific application.  
Note 3. A general rule of thumb for continuous operating temperature for thermal cut-offs is 30°C less than the Maximum  
Opening Temperature.  

与NTE8000相关器件

型号 品牌 描述 获取价格 数据表
NTE8005 NTE Radial Lead Thermal Cutoff

获取价格

NTE801 NTE Integrated Circuit FM Stereo Demodulator

获取价格

NTE8010 NTE Radial Lead Thermal Cutoff

获取价格

NTE8015 NTE Radial Lead Thermal Cutoff

获取价格

NTE8020 NTE Radial Lead Thermal Cutoff

获取价格

NTE8025 NTE Radial Lead Thermal Cutoff

获取价格