NL100
100 Watts Output Power
SINGLE AND DUAL OUTPUTS
FEATURES
•
•
•
•
•
•
•
•
•
.38 Inch Profile
Synchronization
Remote Turn On (TTL)
Output Voltage Trim Pin
Over Temperature Protection
Output Overvoltage/Overcurrent Protection
Built-In Test (Output Power Good)
100% Environmental Screening (Military Version)
Outputs Isolated Allowing Any Combination of
Output Voltages
How to Order:
NL 100 D I / 5 / 15 - A - D
Output Voltages:
One number is
for single output
or two numbers
for dual output.
Maximum cur-
rent as stated in
selection chart.
Options:
Series
A- pins out side of unit
B- pins out bottom of unit
C- pins out top of unit
D- through hole inserts
(STD threaded)
SELECTION CHART
Output Voltage and Output Current
Dual
Total Output Power
Single (S), Dual (D) Output
Industrial (I) or Military (M)
Model Numbering Example:
I - M2.5 inserts
Nominal Output
Single Output
Per Channel
Current (Amps)
To order a 100 watt, 15 V out (single output), industrial grade power supply with pins out the side,
the model number would be: NL100SI/15-A. Military grade would be NL100SM/15-A. To order a
100 watt, dual output, 15 V and 15 V, industrial grade power supply with pins out the top, the model
Voltage
Current (Amps)
2
3.3
5
5.2
12
15
20
20
20
19.2
8.3
6.7
10
10
10
9.6
4.2
3.3
number would be NL100DI/15/15-C. Dual output, 12
V and 15 V, military grade, would be
NL100DM/12/15-C. When ordering a dual output unit, the first output voltage in the model number
is located on channel 1, and the second output voltage in the model number is located on channel
2 (see case drawing for details).
INPUT CHARACTERISTICS
PER CHANNEL
Min.
9
Typ.
12
7
Max.
18
Units
Vdc
Vdc
Watt
mc
%
µA
W
dB
dB
%
Input Voltage
Brown Out (75% of Full Load) [fig. I]*
No Load Power Dissipation
Inrush Charge [fig. VII]*
Reflective Ripple Current [fig. VIII]*
Logic Disable Current (Sink)
Logic Disable Power In
Input Ripple Rejection (120 Hz)
Input Ripple Rejection (800 Hz)
Efficiency (FL) [fig. II & III]*
3.3 Vdc Output (FL)
2 Vdc Output (FL)
OUTPUT CHARACTERISTICS
1
2
3.5
PER CHANNEL
3
100
0.5
50
Min.
Typ.
Max.
1
Units
% V
150
1
✝
Set Point Accuracy
Load Regulation
Line Regulation
Ripple P-P (10 MHz) [fig. IV]*
Trim Range
Remote Sense Compensation
Overvoltage Protection(2V, 3.3V)
Overvoltage Protection (5V-15)
Current Sharing
out
10
5
50
30
25
150
110
mV
mV
mV
% V
Vdc
40
72
70
63
78-85
75
69
out
100
%
%
0.5
140
130
±10
out
% V
% V
% I
EMI: Units conform to MIL-STD-461D (on the input leads) with companion filter
Input Transient: Units can withstand 24V transients for up to 0.1 second
out
out
Transient Response (Vout 1%) Time/Overshoot [fig. V & VI]*
STABILITY
20-80% Load
Low Line - High Line
50-100% Load
300/250
250/200
250/200
0.01
µS/mV
µS/mV
µS/mV
%/°C
Temperature Drift
0.05
0.02
150
75
Long Term Drift
Current Limit
Short Circuit Current
Turn On Time [fig. XI]*
Logic Turn On Time [fig. IX]*
0.01
125
%/1KHrs
0°
out
0 dB
105
20
% I
% I
out
3
3
mS
mS
Phase
Gain
✝
1% or 50mV, whichever is greater
* figures on page 10 represents per channel
100HZ
1KHZ
10KHZ
FREQUENCY
100KHZ
All specifications are typical @+25°C with nominal input voltage under full output load conditions, unless otherwise noted. Specifications subject to change without notice.
Martek Power Abbott, Inc.
2727 S. La Cienega Blvd., Los Angeles CA 90034 USA
http://www.martekpowerabbott.com email: sales.mpa@martekpower.com
TEL (310) 202-8820 FAX (310) 836-4926
NL-B0300REVA
4