Type NHR – SlimpackTM, 3000 hr@150 ºC, Aluminum Electrolytic
Featuring high capacitance at high voltage and temperature, Type NHR-
SlimpackTM offers considerable size and cost advantages over series-parallel banks
of wet tantalum capacitors. Their applications in down-hole tools, military, and
aerospace allow for solutions that use fewer components, lower weight, lower
cost and improved reliability compared with banks of wet tantalum capacitors.
Their rugged construction withstands vibration up to 80g.
Highlights
•
•
•
•
•
•
Alternative to banks of wet tantalum capacitors
No voltage derating required at 150 °C
Rugged, stainless steel case
Near hermetic seal, prevents dry-out
Just 0.5”in height, by 1.0”wide (available in 4 lengths)
High capacitance retention at low voltage, -55 °C
Specifications
Temperature Range
–55 °C to +150 °C
Rated Voltage Range
Capacitance Range
75 Vdc to 300 Vdc
60 µF to 960 µF
Capacitance Tolerance
Leakage Current
20%
≤ 0.006 CV µA, @ 25 °C and 5 mins.
Ripple Current Multipliers
Case Temperature
65
85
105
125
150
2.27
2.27
0-250 Vdc
300 Vdc
5.448 5.221 4.767 4.313
4.767 4.54 4.313 3.859
Ambient Temperature, No Heatsink
65
85
105
125
150
0-250 Vdc
2.4
2.3
2.1
1.9
1
1
300 Vdc
2.1
2
1.9
1.7
Frequency
50 Hz 60 Hz 120 Hz 500Hz 1 KHz 20 KHz
0-250 Vdc 0.65
300 Vdc 0.65
0.75
0.7
1
1
1.5
1.3
1.8
1.4
2.1
1.6
Low Temperature Characteristics
Load Life Test
Impedance ratio: Z–55 ⁰C ∕ Z+25 ⁰C @ 120 Hz
≤ 3 (75 - 300 Vdc
3000 h at rated voltage @ 150 °C
D Capacitance +/- 10%
ESR 200% of limit
≤ 0.004 CV µA, @ 25 °C and 5 mins.
Shelf Life Test
500 h @ 150 °C
Capacitance 100% of limit
ESR 100% of limit
≤ 0.006 CV µA, @ 25 °C and 5 mins.
MIL-STD-202, Meth. 204, Sine Swept. IEC 60068-2-6
JK Case = 80g
All Others = 50g
Vibration
Mounting: Vibration capability is dependent upon mounting
Level
Vibration Test
The specimens, while deenergized or operating under the load conditions specified,
shall be subjected to the vibration amplitude, frequency range, and duration specified
for each case size.
Amplitude
The specimens shall be subjected to a simple harmonic motion having an amplitude
of either 0.06-inch double amplitude (maximum total excursion) or peak level
specified above (XXg peak), whichever is less. The tolerance on vibration amplitude
shall be 10 percent.
Frequency Range
The vibration frequency shall be varied logarithmically between the approximate
limits of 10 to 2,000 Hz.
Sweep Time and Duration
The entire frequency range of 10 to 2,000 Hz and return to 10 Hz shall be traversed
in 20 minutes. This cycle shall be performed 12 times in each of three mutually
perpendicular directions (total of 36 times), so that the motion shall be applied for
a total period of approximately 12 hours. Interruptions are permitted provided the
requirements for rate of change and test duration are met.