CSA
pending
FLATPACK RELAY
NF-RELAYS
FEATURES
1. Flatpack
30.2
1.189
20.0
.787
2. Long seller
10.8
.425
mm inch
SPECIFICATIONS
Contacts
Characteristics (at 25°C 77°F, 50% R.H. seal level)
Arrangement1]
2 Form C, 4 Form C
Max. operating speed
Initial insulation resistance*1
Contact/Contact
50 cps
1,000 MOhm at 500 V DC
Approx. 4 pF
Max.
50 mOhm
25 mOhm
Gold-clad silver
Gold-clad silver
60 W 100 VA
220 V AC, DC
2 A
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Typical
Electrostatic
Contact/Coil
capacitance
Movable contact
Approx. 7 pF
Contact material
Stationary contact
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Contact/Ground
Approx. 6 pF
Between open contacts
750 Vrms
Rating,
(resistive load)
Initial
Between contact sets
1,000 Vrms
breakdown
Between live parts and ground
Between contacts and coil
1,000 Vrms
voltage*2
108
1,000 Vrms
2 A 30 V DC
1 A 30 V DC
0.5 A 30 V DC
2 x 105
106
107
Operate time*3 (at nominal voltage)
Release time (without diode)*3
(at nominal voltage)
Max. 15 ms (Approx. 10 ms)
Expected life
(min. operations)
Electrical
(Resistive)
Max. 10 ms (Approx. 3 ms)
Approx. 1.5 ms
Contact bounce
1].
MBB types available: 2MBB & 4MBB
(See next page for contact positions.)
Min. 29.4 m/s2 {3 G}
(In contact direction)
Min. 98 m/s2 {10 G}
In de-energized
Coil
condition
Functional*4
Destructive*5
2C
4C
Approx. 300 mW
Approx. 480 mW
Shock
resistance
(perpendicular to contact)
Nominal operating power, at 25∞C
In energized
condition
Min. 196 m/s2 {20 G}
Min. 980 m/s2 {100 G}
Approx. 1 W
at 40°C 104°F
Max. operating power for continuous duty
29.4 m/s2 {3 G}, 10 to 55 Hz
at double amplitude of 0.5 mm
(in contact direction)
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
In de-energized
condition
98 m/s2 {10 G}10 to 55 Hz
at double amplitude of 1.6 mm
(perpendicular to contact)
*3 Excluding contact bounce time
Functional*6
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Vibration
resistance
*6 Detection time: 10µs
In energized
condition
117.6 m/s2 {12 G}10 to 55 Hz
at double amplitude of 2 mm
196 m/s2 {20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Destructive
Conditions for operation,
transport and storage*7
(Not freezing and condens-
ing at low temperature)
–40°C to + 65°C
–40°F to +149°F
Ambient temp.
Humidity
5 to 85%R.H.
2C
4C
Approx. 14 g .49 oz
Approx. 15.5 g .55 oz
Unit weight
TYPICAL APPLICATIONS
NF relays are widely acceptable in appli-
cations where small size and high sensi-
tivity are required.
Such applications include: Electronic
equipment, Household applications,
Alarm systems, Office machines, Com-
munication equipment, Measuring equip-
ment, Remote control systems, General
control circuits, Machine tools, Industrial
machinery, etc.
198